Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

how to calibrate hplc & gc

Cipla,

4511

Explain in detail what are the procedure and calculations involved for accuracy (%Recovery)in method validation?

Vimta Labs,

1 6692

WHAT IS DIFFERENCE BETWEEN RRT AND RRF IN HPLC

Cadila,

2 50511

what is mean by Q in S1 and S2

Micro Labs,

3 10928

what is the difference between mcg and ppm?

5 31509

WHAT IS THE DIFFERENT BETWEEN PURITY, POTENCY AND ASSAY

Glochem, Hetero,

6 59171

How we can perform Linearity study for validation by HPLC with very low conc of sample

1 7529

principle of FTIR

Biocon, Macleods,

2 18912

what is separation techniques.

Glenmark,

1 3733

what is the difference b/w repeatability nd reproducibility ?

Aptuit Laurus,

1 10209

why using factor 1.00639 in burette calibration of kf

Cipla,

1 8558

what type of questions asked on analytical balance and also give answers................all pharma companies?

Sun Pharma,

1 12684

Why KBr is used in FTIR ?

6 15684

How to study genotoxicity of impurities in API?

NCL,

2 6386

What is the difference between chiral cel OD-H & OD-RH ?

Aptuit Laurus,

3 11925


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2177


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7549


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2059


how many types of balance calibration test?

2304


how can I make the copper get white bye any salt or acit?

2212


in which situation ion pair require to use?

822


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1822


How do we fix the sample concentaryion in hplc method development. What is the basis?

1210


how require to fix the linearity and accuracy cincentration range?

1672


Hi sir if any product monograph not given known impurities (may be 5 impurities) specifications then how we require to proceed for inhouse formulation?

707


in each media we require to use SLS? how to proceed?

788


why salisylic acid not using now days for disdolution calibration?

777


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1872


What is the use of tlc and hplc? And when and where use?

1168


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1973