Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

whyvibration probe (bently nevada ) is set -10 volt for zero reference?

2 6897

Which buffer solution is used for PH transmitter calibration?

3 7128

For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

5517

what is the formula for calculating milliampere at different pressure points for eg 4-20 ma = 3-15 psi but if i have to check the ma at 4.6 ma?

4 27586

what is three element in thermal boiler

9 13993

what is the conversion factor for nm3 to kg/hr in air flow

4 141065

HOW TO CONVERT 0-60KG/CM2 PRESSURE TRANSMITTER TO A LEVEL TRANSMITTER? CAN WE ABLE TO DO IT? IF YES HOW TO DO IT BY USING HART?

3 9404

how we can measure the interface level?is it possible to measure interface level with dp or pressure transmitter?

2 6085

can any one give me the cost price of yokogawa & rosemount transmitters

4 8852

Is it possible to drill additional gland hole in EExd or EExe JBs? What are the points to take care?

2 5806

WHICH IS BEST INSTRUMENTATION OR ELECTRICAL ENGG?

SAS,

3 7299

can we change the range of 3151 model level transmitter of rosemount make? present calibration range is 1000mmwc and want to change it to 2000mmwc

4 8555

What is difference between converter & transducers?

4 28247

what is buoyancy law?

1 5120

define optical temperature detector

1 5158


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

2334


i am having information technology branh ....... can i prepare for psu exam

2278


IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?

2287


our kks tagging is crossing more than 12 character please suggest how to take tags in the DCS

2118


what are the selections available in configuring a burnout protection of a controller? thanks

2031


Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.

2260


what different types of problems do occur while doing instrumentation commisioning and how to solve them? please explain in detail

1802


How servomotor controls throttle valve of TURBINE?

2015


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1837


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

2277


How does your previous experience relate to the job you are applying for ?

2087


what is different between 2,3&4 wire rtd and how much maximum distance using plc to field.

2835


What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?

3531


Explain the mechanism behind the turbine meter.

1184


How many are the types of instrument cables in terms of No. of pair.

2241