Instrumentation Interview Questions
Questions Answers Views Company eMail

Hot calibrate a level transmitter (wet & dry legs)?

Honeywell, IEC,

1 2778

Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.

1639

POSSITIVE PULSE IS APPLIED TO AN INVERTER INPUT.THE TIME FROM THE LEADING EDGE OF THE INPUT TO THE LEADING EDGE OF THE OUTPUT IS 10 ns. THE TIME FROM THE TRAILING EDGE OF THE INPUT TO THE TRYLING EDGE OF THE OUTPUT IS 8 ns. WHAT ARE THE VALUES OF tPLH and tPHL?

1751

which type inter lock use in petrochemical refinery,and oil & gas?

2625

How a oxygen sensor & analyzer work at boiler or furnace, what’s the principle & science is beyond this, How O2 sensor scene & convert signal & move toward analyzer & analyzer show reading in percent?

GS Engineering Construction, KNIC,

1 4970

How to convert mA into Percentage?

KNPC,

4 30007

A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

MNC,

1679

can i calibrate DP transmitter online (while Tx in Service) if yes ,how?

CEPC,

1 4632

I have a orifice installed in plant which is design for 0~100 inH2O for 0~80MMSCFD, now due to process change the maximum flow is change to 120 MMSCFD so for this new process value what will be the DP across orifice.

1 7202

what is positive feedback and negative feedback?

CEPC,

2 5123

without color coding, without nameplate, without multimeter how can you find the type of thermocouple???

Sabic,

1 5548

why r using 250 resistances

Sabic, Samsung,

6 9406

Explain level troll principle & interface level measurement.

ADMA OPCO,

1 4287

What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

ADMA OPCO,

1468

i want the equation of this question. Tranmitter range is 120 mmwc and dcs flow range is 1700 nm3/hr. if i want to change dcs range from 1700 to 2400 nm3/hr then how much dp i have to enter in transmitter

GMR,

2 11537


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

where cascade loop use ?

1305


1.can you use SCADA instead of DCS,DCS instead SCADA 2.Difference between DCS and PLC,can their role be reversed i.e. role interchange 3.Difference between RTU and PLC

2061


in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.

1570


our kks tagging is crossing more than 12 character please suggest how to take tags in the DCS

1659


What is the use of double seated valve?

726






I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1565


I need to know steps to Calibration Valve Guard......

982


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

2284


a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error

1843


what is the calibration procedure for magnetic flow meter @ onsite

1195


What is profibus?

642


䑰ҕ䔈ҕ䖠ҕ䘰ҕ䛀ҕ䝐ҕ䟐ҕ䢐ҕ䥐ҕŹ

1509


In apron feeder how TPH is calculated?

1177


How to Calibrate Ultrasonic Level Transmitter in field

799


How INtools is useful for routine Instrument maintenance?

1562