please explain clearly in PID controller if We increase P only what will be action of the contrlere.
1 5626yokogawa Temperature transmitter showing Error 15 which is Reverse Cal Fail (confirmation calculation result is bad) in manual they mentioned reasion That the output goes to the value set by hardware failure mode jumper. How can solve this problem ? anybody can say solution
GTL,
1 6989Furnace draft transmitter range is -50 to +50 mmwc. why the impulse line connected in hp side?
2 13720Good Evening all.My question is - For a feed water line to an equipment if i need to measure the flow we will use orifice /magnetic/vortex depend on cost/spec.If i need to measure a ''Alarm''signal and ''Interlock'' from one point i think we can use orifice type in one location with 2 different tapping points - one for alarm and one for an interlock to flow valve..If in case i need to have both these signals(Alarm & interlock) from magnetic flow meter,is it possible??will 2 seperate sensors will be located inbuilt r we can program it ??..i thk we can have one transmitter with these 2 signals...need to know any technical issues are there?pls clarify
3 5370Post New Instrumentation Questions
Define cryogenic?
why using negative supply for bentley nevada vibration system ?
protection relay watchdog contact operation?
give me all the details about the interview and which type of question being asked
how to calibrate Necleuonic level transmitter.?
What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?
if my flow is 20000 m3/h than which range of DPT i have to use????
god evening sir i am studying m.sc(tech)electronics &instrumention.am i elegible to all industies
how to calculate range of level transmitter?
what is vibration a part of proceess variable? if vibration is a part variables then how we minimize the actual vibration on machine on load,? vision of instrumentation contrl plz ans me IPGDL interview question
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?
Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?
Hi Friends , i need one urgent help , i am preparing for M.tech entrance examination , i need some obejective questions related to instrumentation field. where can i get those ? can anyone help me pls ?