please explain clearly in PID controller if We increase P only what will be action of the contrlere.
1 4034yokogawa Temperature transmitter showing Error 15 which is Reverse Cal Fail (confirmation calculation result is bad) in manual they mentioned reasion That the output goes to the value set by hardware failure mode jumper. How can solve this problem ? anybody can say solution
GTL,
1 4872Furnace draft transmitter range is -50 to +50 mmwc. why the impulse line connected in hp side?
2 10378Good Evening all.My question is - For a feed water line to an equipment if i need to measure the flow we will use orifice /magnetic/vortex depend on cost/spec.If i need to measure a ''Alarm''signal and ''Interlock'' from one point i think we can use orifice type in one location with 2 different tapping points - one for alarm and one for an interlock to flow valve..If in case i need to have both these signals(Alarm & interlock) from magnetic flow meter,is it possible??will 2 seperate sensors will be located inbuilt r we can program it ??..i thk we can have one transmitter with these 2 signals...need to know any technical issues are there?pls clarify
3 3316Post New Instrumentation Questions
What is modbus?
Describe a time when you anticipated potential problems and developed preventive measures.
what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .
how to work static pressure sensore how to work dpt
What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
In apron feeder how TPH is calculated?
In most instances, Inertia processes are quite uncommon. Give an example of a combined Resistance and Capacitance situation.Describe an application, which according to your understanding of the subject matter, comprises of both Resistance and Capacitance effects.
what is the calibration procedure for magnetic flow meter @ onsite
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
can any one explain in which term we are flow flow is it volumetric r is it mass? and y
What you mean by multi stage control vavles?
How does temperature bath work? How does coil gets heated only by applying some current?
Do you have reference list?
How do bending tubing provide better measurement than using tubing fittings such as elbows?