why high pressure heater will take after sufficient pressure?
what happen when high pressure heater will take from COLD
REHEAT line at light up time when hp and lp by pass in
service.(means can we heater take at low pressure?)

Answers were Sorted based on User's Feedback



why high pressure heater will take after sufficient pressure? what happen when high pressure heater..

Answer / chinmay kumar patra

feed water temperature will be very high ie above design temperature.so super heater temperature will be very high .there is a chance of SH tube rupture due to less heat exchange.also we have to load gradually and loading on BFP will be more.

Is This Answer Correct ?    1 Yes 0 No

why high pressure heater will take after sufficient pressure? what happen when high pressure heater..

Answer / chetan h malaviya

We can take CRH extraction line(HPH 6) in line during lit up but at that time pressure of CRH line must be >5 kg/cm2 and corresponding degree of super heating must be >100 'C

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Power Plant Engineering Interview Questions

what's interlock relay ?

3 Answers   International Mega Food Park Limited, National Power Training Institute NPTI,


what is IR in differential test on motor?

2 Answers   Adani, Adani Power,


In a thermal power plant ID Fans running with full load but boiler load is only 80 % give reason ?

9 Answers   Essar, Prumatech, Tata Power,


can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

0 Answers  


What is critical speed of turbine

6 Answers   Vasavi Power,






what are the major duties of a instrumentation engineer in a power plant.?

3 Answers   Gulf,


What are the effects of corona in switch yard.

1 Answers   JSW,


What is difference between secondary Air & Tertiary Air and Their use.?

0 Answers   Bhel,


Why reheater is not used after IP turbine.

3 Answers   Hindalco, SEC,


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

0 Answers  


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

0 Answers   Student,


What is indipendant power plant

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)