what is scanner air fan & how dose it work & is there any
interlock in power plant
Answers were Sorted based on User's Feedback
Answer / bnbnbnb
Scanner air fans are small fans ( Both AC & DC) for supplying cooling air to scanner head.
Scanner heads are placed near the fuel nozzle of every elevation to monitor the fireball of the furnace.
Is This Answer Correct ? | 35 Yes | 2 No |
Answer / sunny sharma
Scanner air fans are small fans ( Both AC & DC) for supplying cooling air to scanner head.
Scanner heads are placed near the fuel nozzle of every elevation to monitor the fireball of the furnace. Taking suction from FD fan if fd fan trip than it will take suction from atmosphere air
Is This Answer Correct ? | 21 Yes | 1 No |
Answer / brajesh_genus
nothing but to remove flame scanner lance dust & taking
suction from atmosfier air and purging to lance & no interlock.
Is This Answer Correct ? | 6 Yes | 11 No |
What happen when the AVR of the generator fails? Will it cause power instability and total failure of the alternator?
Why cold water is used for Boiler Hydro test
what is need of primary water system in power plant?
a gas turbine have how many thermocouples?
why oil filled transformers will be with explosion and fire often?
What is MFT and when it is acted.
why seal air fan is used and where it is used and where is suction taken from
How to calculate air to fuel ratio in boilers
What are the turbine protections.
why do we use contro fluid tank (cft)in turbo generator area(tg) in power plant?
operation
what is the difference between kg/cm2 to MMWC