working of a diesel generator.
Answers were Sorted based on User's Feedback
Answer / guest
by using a diesel operated motor the mechanical input to
the generator is given and the generator generates the
electricity
| Is This Answer Correct ? | 449 Yes | 88 No |
Answer / manoj sharma
A diesel generator is the set of diesel engine and
alternator. Disel engine is prime mover which rotates the
alternator and alternator generates the electricity.
Further diesel engine works on principle of carnot cycle,
air is compressed in a cylender, then it is compressed up
to high pressure, disel is injected to this compressed air
thus cumbustion takes place,this energy force to move the
piston in the cylendrical passage, piston is further
connected to crank shaft. on the other hand generator
wotrks on principle of electo magnetic induction, when a
DC excited rotor is rotated then at synchonous speed EMF
induced in static armature.
| Is This Answer Correct ? | 265 Yes | 25 No |
Answer / apurb prakash
Diesel is used as fuel for the generator.disel prodused
mechanical energy with the internal construction of
generator.then this mechanical energy is converted into
electrical energy
| Is This Answer Correct ? | 218 Yes | 43 No |
Answer / vijay
genrator is a machine which use diesel as fuel to run the
engine which rotate the rotor of an altenator which produse
the electricity.
Basically genrator is a machine which convert the machnical
energy into electrical energy.
| Is This Answer Correct ? | 154 Yes | 28 No |
diesel generator worked as principle of faraday's law of
electromagnetic effect.mechanical energy is converted to
electrical energy.It can stared to d.c supply i.e. 12v ,
24v.D.C supply to starter and after starting it produce
A.C. supply.Engine only use as a prime mover.
| Is This Answer Correct ? | 106 Yes | 32 No |
AS PER MY FIELD EXPERIENCE .IN DG SET DIESEL IS USED FOR
FUEL OF STROKE ENGINE,SO THE ENGINE PRODUCED MECHANICAL
ENERGY .THE SHAFT OF ENGINE IS COUPLING WITH GENERATOR
THEREFORE MECHANICAL ENERGY CONVERTED INTO ELECTRICAL
ENERGY .BY USING GOVERNOR WE CAN ADJUST THE SPEED OF THE
ENGINE .&WE CAN DEVELOPING OR CONTROLLING THE DG OUTPUT
VOLTAGE BY USING AVR(AUTOMATIC VOLTAGE REGULATOR).THE
CONTROLLING & DISPLAYING OF GEN SET IS OPERATING BY DC
VOLTAGE FROM BATTERY .WE CAN CHARGE THE BATTERY AT THE TIME
OF ENGINE RUNNING BY USING THE CHARGING ALTERNATOR.ITS
COUPLED WITH ENGINE SHAFT THROUGH BELT .FOR THE SAFE WE
USING STARTER MOTOR TO START ENGINE THATS MOTOR OPERATED BY
DC VOLTAGE .
| Is This Answer Correct ? | 73 Yes | 9 No |
Diesel Generator is a set of engine and alternator.
(Which converts mechanical energy in to electrical energy)
here engine is using for rotating the shaft(prim mover or
crank shaft).
Rotation takes place as fallows:
1)The pistons placed in cylinders and these pistons are
connected to Crank shaft through connecting rads
2)By using diesel as a fuel the blasting takes place in
cylinders, this blasting energy can be converted in to
rotation through piston,connecting and crank shaft
3)this rotor speed strength(should be synchronous
speed)depends on firing order of the cylinders (of course on
number of poles on rotor)
4)this shaft is connected to Alternator rotor
5)this rotor contains poles, this rotor will get the D.C
supply from A.V.R through Exciter (RRA: Rotating Rectifier
assembly, it is a converter bridge)
6)So with rotor(poles) rotation the EMF will induce in main
Stator(Faraday's law of electro magnetic effect)
7)A.V.R out put depends on load effect on D.G.
((for further full detail call me at 09458490849)
| Is This Answer Correct ? | 53 Yes | 5 No |
Answer / aayush
A diesel generator works on the principal of Faraday's law
of electromagnetic effect. Mechanical power of the rotor is
converted into electrical power. As the rotor rotates
(because of the external voltage given to it through the
battery), EMF and hence current is generated, which is
collected by collectors connected on the stator.
| Is This Answer Correct ? | 67 Yes | 22 No |
Answer / v.dhamodharan
generator is a mechanical convert electrical it is a multi
purpose used generator
tower section mainly used generator .
EB power off generator used gen is absent tower is down
| Is This Answer Correct ? | 74 Yes | 39 No |
Answer / gagan deep singh
Generator: IT IS A MECHANICAL DEVICE WHICH IS USED FOR
CONVERTING THE CHEMICAL ENERGY STORED IN FUEL TO THE
ELECTRICAL ENERGY. IT CONSISTS OF FOLLOWING COMPONENTS
1.DIESEL ENGINE
2.TURBINE
3.ALTERNATOR
4.COIL WITH PRIMARY $ SECONDARY WINDING OF COPPER WIRE.
1.DISEL ENGINE CONVERTS CHEMICAL ENERGY INTO MECHANICAL
WORK.
2.TURBINE CONNECTED WITH CRANSKHAFT OF ENGINE ROTATES
IN THE CORE(STATOR.
3.ALTERNETOR CONVERTS MECHANICAL ENERGY INTO ELECTRICAL
ENERGY.
4.WINDINGS ARE USED TO STEP UP OR STEP DOWN THE VOLTAGE.
| Is This Answer Correct ? | 57 Yes | 23 No |
What is accuracy of a measurement?
what is the path of thunderlightening? once both a buffalo and a person were standing 5m apart but lightening hit and killed buffalo not person?
As the one point of eac phase winding is connected to each other in satr connction. Even if that at distribution side collesion of two diff phases result in to blast. Why?
can i know how to design overcurrent setting and earth fault for 11kv & o.433kv system assuming tx 1000kva.
i heard that power factor(PF) is the main concern for industries, if they are maintaining PF around 0.6 they will be fined for that. now the question is, how can they improve the PF ranging between 0.9 to 0.95 which is safe for them i,e escaping from the fine?
why neutral is required in electrical system
IN MCCB AND MCB TERMINATIONS ARE IN-COMING ON TOP AND OUT GOING ON BOTTOM,IF WE TERMINATED INTERCHANGED TOP AND BOTTOM ITS WORKS?
What's the difference between non break power supply and non break non short break power supply
How to know any size of cable if there are not written on cable? Answer must be theurical not by experience.
A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram
what will happen at secondary side of transformer if i increase voltage at primary side?while V1*I1=V2*I2 will secondary voltage or current increase?
in thermal power plant the steam produced is made to cool after falling on the turbine blades. my question is why this is done while the same is needed to heat up again. "jab pani ko wapis garam hi karna hai to thanda kyu karte hai"
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)