Engineering AllOther (1379) Dear Friends, I have a 500KVA transformer supplying whole factory having 3 phase and single phase mixed loads. Power room has ammeters connected via CTs for individual phase. Now I know that readings shown on meter for each phase say R,Y and B are line currents. But when I want to know the total on transformer do I need to add the currents of all three phases readings shown on meter or value for anyone phase will give me the correct power load on transformer for that point of time. 2. If ammeter shows unbalanced readings for R,Y, B phases say 150, 250 and 300 respectively so can I assume that 150A i.e average of 3 will be the 3phase load currents and remaining will be 1phase currents. Please clarify my doubt.
4 7663Respected Sir, I am from a hilly place called Darjeeling ,I have constructed house of 9 column out of which 4 of the column is under water , i have put rcc slab on top and on top of the rcc slab i have construced two room house with bricks and light roof , now i am planning to change the light roof with rcc slab for the two room, my main concern is will the column under water will hold the load of the new rcc slab coz it already 10 to 12 yrs old , i dont know what to do , can u advice me regarding this matter, weather to leave the upper floor roof light or make it rcc slab.(If i put the slab , it will require 45bags of cement and u calculate how much of steel and sand and pebbles) thanks with regard Anand
2 5060
how to select electronic timer(Star-Delta) setting for diff. rating motors
we use parallel flow heat exchanger to coo oil of 1000 EP viscosity,oftenly tubes may damage during cleaning etc what is proper way to clean cooler? How impurities decreased or vanished during working or in less teme job performed?
What happen to generator if i have unbalanced load?
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
What is the work of Bus cable, Power cable and Er cable in nokia flexi edge bts.
i have done B.TECH in che.tech.and doing MBA . why you doing mba why u have not join any job.
What is the difference between DOL starter and star delta starter
If P will increase then what will happen with PID?
explain safety measures in alternator?
Which one of the following polarization mechanisms/sets of mechanisms contribute to the static dielectric constant of a homopolar neutral dielectric?
from generating station If 400v LT line length is 1000m how much voltage is drop and how do i calculate it? which cable will be use for this line?
In cement concrete how to check a quality of material also proportion of material at site ?
List two effects of manganese in plain carbon steels?
You have 3 snd sample of different FM=0.21,FM=0.95,FM=2.90 which one is suitable for a)plastering on R.C.C b)plastering on masonary wall c)concreting column d)concreting of bored pile.also justify your answer.
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?