Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) If an ID Fan is designed for a suction pressure of - 250 mm wg and discharge pressure of +150 mm wg, and it is installed in a system where the required system resistance at suction is only -50 mm wg, will the ID Fan be able to produce a discharge pressure of +350 mm wg?
1 2308During FEED, you will have all the information with regards to cable. How will you calculate the MTO for MV and LV Cables? what are your considerations?
2479
Why the symbol of register is "zig zag"
When we connect the large capacitor bank in series ?
if the nitrates more than 45mg/l in water lead to disease then what is it called
Why we used 690V in ACS 800 drives.Why dont use standard voltage like 415v or 1.1Kv
how much shouid be the rate for ready mix concrete per cubic meter
what are the pecularity of shaver sockets ?
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?
Why is steel vital in the construction of an aircraft?
how work microwave anteena in mobile tower
How Self works in DG set
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Silicon carbide reinforced aluminium metal matrix composites find application in
what is meant by absorptivity?
Write the force balance equation of m ideal mass element.