Respected Sir,
I am from a hilly place called Darjeeling ,I have
constructed house of 9 column out of which 4 of the column
is under water , i have put rcc slab on top and on top of
the rcc slab i have construced two room house with bricks
and light roof , now i am planning to change the light roof
with rcc slab for the two room, my main concern is will the
column under water will hold the load of the new rcc slab
coz it already 10 to 12 yrs old , i dont know what to do ,
can u advice me regarding this matter, weather to leave the
upper floor roof light or make it rcc slab.(If i put the
slab , it will require 45bags of cement and u calculate how
much of steel and sand and pebbles)
thanks
with regard
Anand
Answers were Sorted based on User's Feedback
Answer / kohinur
Darjeeling is under high danger earthquake zone.So light weight roofing is best for your house. Your columns in water also a big concern. Because how you constructed and what design parameter considered during construction also a great concern. It is advisable to consult with a structural engineer before it's modification. How ever you are advising to stay with light weight roof and ensure the earthquake safety bend like plinth bend, seal bend, lintel bend and roof beam with stable structure and foundation.
| Is This Answer Correct ? | 2 Yes | 0 No |
Answer / sudin shaha
sir,
you must consult your r.c.c consultant for by what factor of
safety they have considered and for how many storied bldg.
| Is This Answer Correct ? | 0 Yes | 0 No |
Maximum foundation pressure under PRCC box is 19 T/Sqm and net safe bearing capacity is 12.65. Is it safe? pl help me
how can we determine the quantity of steel bars in a structure? is there any formula for determing the number of bars required ?
do we decide reinforcement steel , based on bending moment ? give example with continous slab?
Which apparatus done steel (bar) tension test
how much required strength of cement concrete bricks(size 230x115x75mm)
What in bending moment, if a moment is free end of cantilever beam?
What is Bearing Capacity of Soil? How will you calculate for a particular type of Soil?
5 Answers Nagarjuna Construction,
How can i design the beam . Explain with one example
i have four storeyed rcc building.basement of the building is around 34 years old.it does not have pillar support.it is having lintel steel support at every 7 feet of construction. how long this building will lost long . can any body help me in this regard
what is escalation?how it is done?
is there any information regarding MPSC2010
What do mean by freeway ?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)