which is greater moment at centre or fixed end moment for a
fixed beam with udl

Answers were Sorted based on User's Feedback



which is greater moment at centre or fixed end moment for a fixed beam with udl..

Answer / raghavendra

Fixed end moments are the greater moment.

Is This Answer Correct ?    39 Yes 5 No

which is greater moment at centre or fixed end moment for a fixed beam with udl..

Answer / cantilever

moment is greater at end wl*l/12 and at centre wl*l/24

Is This Answer Correct ?    17 Yes 1 No

which is greater moment at centre or fixed end moment for a fixed beam with udl..

Answer / sachinprakash05

fixed end

Is This Answer Correct ?    9 Yes 0 No

which is greater moment at centre or fixed end moment for a fixed beam with udl..

Answer / jbhhv

at the centre

Is This Answer Correct ?    18 Yes 18 No

which is greater moment at centre or fixed end moment for a fixed beam with udl..

Answer / krishna kumar

as the ends are farther
from load acting points
ends has more moment as
the moment itself product
of distance and load

Is This Answer Correct ?    0 Yes 0 No

which is greater moment at centre or fixed end moment for a fixed beam with udl..

Answer / dvn potharaju hyderabad

For simply supported beam fixedend moment is max at ends
only


fixedend moment @ support is wl*l/12
fixedend moment @ centre is zero

Is This Answer Correct ?    2 Yes 9 No

Post New Answer

More Civil Engineering Interview Questions

what is the factor of safety for cement and steel with reference to IS 456-2000. and min reinforcement should be provided for column and slab with reference to IS 456-2000.

5 Answers  


Should vertical shuttering done for CC/ RCC for Damp Proof Course (DPC) be measured?

2 Answers  


what"s the difference between fe 415 grade steel and fe 500 grade steel? and which one is mostly used for residential and apartment constructions?

6 Answers   L&T, SkyTech,


For a three storey residential house,tmt steel of what grade is good fe415d or fe500d

2 Answers  


distinguish between under reinforced and over reinforced beams?

2 Answers  






y we need to take 28 days strength as compressive strength ? y cant we take 30 th day

2 Answers  


CAST EFFECTIVE WATER SUMP CONSTRUCTION DETAIL

0 Answers  


why development length = 50D . why not 100D

0 Answers  


I have an span length 16 ft c/c

0 Answers  


How to calculate the force on a column of three story building. What should be the base concrete height?.

0 Answers   C&C,


How many jacks and props required for one floor, or tell me any thumbrule...to know the approx jacks and props required.?

1 Answers   Sumadhura Infracon,


can we go for short rcc column without any steel rienfocement carrying truely axial load???

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5084)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16631)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1094)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)