Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


in cvt,there are two windings,1a,1n and 2a,2n.in my one
project i use only one winding i.e.1a,1n. the other winding
is not in use, so i connect it in open delta and want to
close it by ibsertibg thermal resistor. the output of cvt
is 132kv/115/sqrt3. plesae tell me exact value of resistor,
so i may close it to avoid the resonance phenomenin. send
me answer on this email adress please.
aetcon-po@aetcon.com


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Electrical Engineering Interview Questions

what will happen if i commission a transformer without connecting the neutral?

2 Answers   L&T, Sail,


how much earth resistance consider to commissioning the transformer?

3 Answers   Deccan Cements,


Why is the starting current high in a DC motor?

2 Answers  


why we are discharging h.t supply during shutdown time

1 Answers  


What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.

0 Answers   GNFC,


What is the technical difference between IS:1554 and Indian Railway IRS:S63/2007

0 Answers   Indian Railways,


what is the difference b/w neutral and earth?what is the need of earthing and what are the different methods for earthing?

4 Answers   NTPC,


how to control the speed to switched reluctance motor

0 Answers  


There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.

0 Answers   GMR,


we have two 11/.433 kv. distribution Transformer rating as 1000 kva & 500 kva , i wants to run parallel both transformer. both transformer impendence voltage is 5.24%, How can we run both t/f, & how sharing the load

3 Answers  


what is allowable current flows from phase to ground with out tripping the breaker

1 Answers  


What is maximum rating of transformer ?

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)