Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


how to test the ht machines?


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Electrical Engineering Interview Questions

HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?

0 Answers   TMB,


how to select the surge suppresor for the 33 KV supply and what will be the rating, selection guide

1 Answers  


If cvt is most advance & effective(economically & stability)so why not use instead of VT(11 kv & 33 kv)?

3 Answers  


define reactive power?

3 Answers   Alstom, TATA, TCS,


What is the correct procedure to shutdown VCB in 11kv substation.safety and work procedure

3 Answers   EGA,


If the secondary winding will be open in current transformer, how to damage the insulators

2 Answers   TPDDL,


I have raw material for making Compact-Choke for flourscent lamp of 40 Watts. We are suppose to get 0.4 amps output at end. but we are getting 0.42 or 0.44 amps and above. We have done many testings in different but nothing worked out. Please suggest me how to get the correct output. We are using 1. core winding of 700 windings of aluminium 2. E-shape iron fillings and I-shape iron fillings to surround the winding.

6 Answers  


How can we findout the maximum efficiancy of Transformer? At which load?

0 Answers   HAL, Tanfac,


give me list of material for wiring of 20hp motor?

2 Answers   Alchemist,


How can we calculate No load and full load torque of electrical machines, i.e. motor or alternator?

1 Answers  


1) Why distributiion system decided 11 kv, 33 kv, 66 kv, 132 kv, 220 kv, 400 kv, 2) In 3 Phase line terminal of capacitor, why used for power factor improvement. 3) Why used rating KVA in transformer?

1 Answers  


What is the Power factor of DC Power system ?

9 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)