Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How to measure high frequency using thermistor



How to measure high frequency using thermistor..

Answer / jobby c johnson

thermistor is basicaly a temp measuring device.
At 25deg it is having a resistance value typically of 60k.
if we are placing thermistor in ac or in dc bridges then
the resonant frequency depends on the the value of
resistance. it is a useful measure for measuring high
frequency

Is This Answer Correct ?    5 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

what is sequence table in DCS . make a logic in sequence table for tripping of ID fan in Boiler(in YOKOGAWA CS 3000 DCS).

1 Answers   Yokogawa,


hw to calibration a control valve?

3 Answers  


1)What is the suitable MOC for flow meters working at temperature between 200 - 250 cen. 2)In which application the mass flow meters are not advisable 3)Is it advisable to use radiation type or radar type instrument for non contact application

1 Answers  


What is hp & mp seperator .& what is its working principle ?

0 Answers  


what is vibration sensor working principal and how many types its has??

5 Answers  


Calibration procedure for electro magnetic flow meter

0 Answers  


WHY WE R NOT USING THE TURBINE FLOW METER IN THE STREAM SERVICE ? pl explain?

3 Answers  


why flow transmitter showing 2.2ma?

2 Answers  


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

0 Answers  


In close vessel/ drum why we use d.p. transmitter of -ve range i.e. (-)500 to 0 mmwc.

2 Answers   IMECO, Voltech,


Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...

0 Answers   Adgas, GAIL, Oil India, ONGC,


What is surge and how is it prevented.

1 Answers   ADMA OPCO,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)