Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Which is the best mobile phase to separate organic acids using C8 column. And how should the samples be prepared for hplc?



Which is the best mobile phase to separate organic acids using C8 column. And how should the samples..

Answer / s chatterjee

http://www.restek.com/Technical-Resources/Technical-Library/Foods-Flavors-Fragrances/fff_FFAR2062-UNV

100 % aqueous buffer is the choice, ideally pH 2.8 phosphate

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

iam usig ph buffers merk. manually how to prepare ?

0 Answers  


in which situation ion pair agent require to use?

0 Answers  


why octanol used to determine the partition coefficient ?

0 Answers  


what is relationship between absorption and transmittance in u.v.?

11 Answers   Orchid,


Can we do the MC analysis of a sample which is not completely soluble in the medium choosed.

2 Answers  


In chromatograpbic purity 90% is there, in assay 70% is there. How will you prove remaining 30%.

3 Answers   Dr Reddys,


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

0 Answers  


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

0 Answers  


if instrument calibration fails then what require to do?

0 Answers  


What is Temperature ?

2 Answers   Reddy Labs,


What is zero water in TOC Analysis?

1 Answers   Orchid,


Is it necessary to inject three replicate for accuracy in AMV.

1 Answers   Amoli Organics,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)