Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In dissolution of tablets/capsules elaborate the Dissolution limit 20.0% to 60% Q in 30 minutes.



In dissolution of tablets/capsules elaborate the Dissolution limit 20.0% to 60% Q in 30 minutes...

Answer / jignesh

Dissolution range in given in ER tablet.
so perform first 6 tablets and all of them fall within 20.0% to 60.0% than tablets pass in S1 stage.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

which procedure we follow if 6th month of accelerated sample fail?

1 Answers   Dr Reddys,


What is the formula for relative diffrence for standard solution in solution stability in validation?

0 Answers  


if v use HELIUM & ARGON instead of NITROGEN as a mobile phase what happen in GC SYSTEM ?

5 Answers   Cipla, Reddy Labs,


what is the difference between M.C and LOD

21 Answers   Aurobindo, Cipla, Laurus, Matrix, Synthokem Labs,


on what basis SOP's can be changed? IF mobile phase ratio is 70:30 to how much % can we change the ratio in HPLC process

7 Answers   Cipla, Ranbaxy,


Why linearity of detector performed in HPLC calibration

2 Answers   Cipla, Intas,


What is the principle of HPLC, GC, LCMS, GCMS,LC QQQ, GC QQQ, LC Q TOF and GC Q TOF. What are the applications and Specificity?

0 Answers  


In Force degradation Study Compound is not degrade in any condition , also in higher stress what can i do ?

4 Answers   Alembic,


How can we calculates the solubility of the drug in different medias by injecting in to hplc????(solubility studies)

2 Answers   Super Pharmaceuticals,


why salisylic acid not using now days for disdolution calibration?

0 Answers  


what is the identification test of volatile substance? what is volatile compound?

1 Answers  


what are the sources in ELSD,PDA, RI and UV Detectors?

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)