Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In Stability testing if significant change occurs then what
will be the action plan?

Answers were Sorted based on User's Feedback



In Stability testing if significant change occurs then what will be the action plan? ..

Answer / udaya

if significant change occurs in stability studies, we have to select subsequent condition means if we observe significant change in long term then go to refigerator condition as it is if accelerated condition then go to intermediate continue the which month you are observed significant change. if these conditions also significant change occurs then change the packing condition of sample if we are packed the sample in outer black and inner double polythene white bag then go to keep silica gel otherwise TLMB bags like this.

Is This Answer Correct ?    6 Yes 1 No

In Stability testing if significant change occurs then what will be the action plan? ..

Answer / j.naresh babu

After closing the investigation against the significant
change occurs in which condition, then go to further
stability testing conditions, ie if accelerated conditions
having significant change then go to Intermediate
conditions, if Long term conditions having significant
change then go to Refrigerator conditions.

Is This Answer Correct ?    3 Yes 2 No

Post New Answer

More Analytical Chemistry Interview Questions

How can we determine Moisture content of HI?

1 Answers   Cipla, Reddy Labs,


What is post run in hplc?

1 Answers   Cipla,


How do u differentiate primary

1 Answers  


How to set specification of assay, fisdolution and related substances?

0 Answers  


how calculate column dead volume in hplc ?

3 Answers   Torrent Pharma,


stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc test is replaced with hplc test. At the 4th year frequency the product is failed in hplc test .how can i assain the expiry or retest date and can i stop or continue the programme?

2 Answers   Nakoda Chemicals,


If compound Pka is 5 then which buffer you will select ?

5 Answers   Avra, GVK,


Why forced Digradition Study is done

6 Answers  


what is the principal of malvern particle sizer & its used in pharma industry

3 Answers  


What is split ratio in Gc? Splitless? how requirr to select?

0 Answers  


A new drug substance found fail to meet specification for an unknown Impurity during stability study(Specific change),how would further proceed?

2 Answers  


What is reaction takes place when water content analysis is done

2 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)