Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why ct secondary is not kept open while primary charged. Answer in terms of ct parameters.

Answers were Sorted based on User's Feedback



Why ct secondary is not kept open while primary charged. Answer in terms of ct parameters...

Answer / aashish

Because a very high voltage is generated in the secondary due to large no of turns so if open circuited ct will get damage

Is This Answer Correct ?    14 Yes 1 No

Why ct secondary is not kept open while primary charged. Answer in terms of ct parameters...

Answer / raja

Understand CT is a voltage step up transformer.

HT side has higher voltage but low current.
LT side has lower voltage but high current.

So for CT of rating 500/1 Amps, 500 Amps side(Primary of CT) has very low voltage and 1 Amp side (Secondary of (CT)
has very high voltage(Insane value in KVs).
 
This high voltage is beyond the maximum impulse withstand voltage of the CT and it blasts the CT. Hence secondary is always short circuited.

Current and voltage are inversely proportional. 

Is This Answer Correct ?    5 Yes 0 No

Why ct secondary is not kept open while primary charged. Answer in terms of ct parameters...

Answer / vipin singhal

when secondary is open then in primary flows very large current which burn the winding of the core.

Is This Answer Correct ?    8 Yes 4 No

Why ct secondary is not kept open while primary charged. Answer in terms of ct parameters...

Answer / gautam

 if we open circuit the secondary terminal current across this terminal falls to zero. as VI is constant for a Xmer voltage across secondary side increase drasticly,which results electrical breakdown across secondary.

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

why we use the fuse in only one wire? althrough in ac current the current flows in both directions. why the neutral wire can be taken half the magnitude of phase wire while same current returns from neutral wire?

2 Answers   Bhel,


IF we have 500kva transformer & know the current on HT & LT side, how can we consider for its breaker?

5 Answers  


Why HT 11 KV Slipring Motors are connected in star ?

0 Answers  


DEAR SIR,I GOT THE CALL LETTER FROM RRB, SECUNDERABD AS A JE-II SO PLEASE PROVIDE ME SOME MODEL QUESTION AND ANSWER PAPERS AND LAST YEAR QUESTION PAPERS

0 Answers  


What is reactance? what is the function in Auto transformer and why high leakage reactance?

1 Answers  


how to carried out DAR test in 11 KV Alternator ?

0 Answers  


How we calculate DC inducation moter Amp? Sir pls give me formula......

0 Answers   Superlite,


Why is the uniform distribution of the capacitor discs in a suspension type insulators essential , what can u do to improve the string efficiency ?

1 Answers  


Differentiate between digital phase converter and ordinary phase converter.

0 Answers  


Before i went to bed my master bathroom lights were working fine. At 2 am, when I went to use the lights, none of them were working. The outlets throughout the bathroom work, but the lights and fan above the toilet don't. I have two panels of switches. The one panel has four switches. One of the switches turns on the hall light, and that works. The other three are to other lights, and they don't. The other panel has three switches. One of those is to the fan, and the other is to a light above the toilet. The other is a to light that is also on that other panel. I tried the breakers, and the one that turns off the outlets, marked for the bathrooom, turns on and off the outlets. None seemed to be tripped. I checked the lightbulbs, and they are fine. Please help

2 Answers  


what is meant by leakage current of a capacitor?

1 Answers  


what is MULTIPLYING FACTOR in substations??

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)