How do you recover rows from a failed session
Answer / thotli
through recovery strategy:resume from last check point
| Is This Answer Correct ? | 0 Yes | 0 No |
How can the following be achieved in 1 single Informatica Mapping. * If the Header table record has error value(NULL) then those records and the corresponding child records in the SUBHEAD and DETAIL tables should also not be loaded into the target(TARGET1,TARGET 2 or TARGET3). * If the HEADER table record is valid, but the SUBHEAD or DETAIL table record has an error value (NULL) then the no data should be loaded into the target TARGET1,TARGET 2 or TARGET3. * If the HEADER table record is valid and the SUBHEAD or DETAIL table record also has valid records only then the data should be loaded into the target TARGET1,TARGET 2 and TARGET3. =================================================== HEADER COL1 COL2 COL3 COL5 COL6 1 ABC NULL NULL CITY1 2 XYZ 456 TUBE CITY2 3 GTD 564 PIN CITY3 SUBHEAD COL1 COL2 COL3 COL5 COL6 1 1001 VAL3 748 543 1 1002 VAL4 33 22 1 1003 VAL6 23 11 2 2001 AAP1 334 443 2 2002 AAP2 44 22 3 3001 RAD2 NULL 33 3 3002 RAD3 NULL 234 3 3003 RAD4 83 31 DETAIL COL1 COL2 COL3 COL5 COL6 1 D001 TXX2 748 543 1 D002 TXX3 33 22 1 D003 TXX4 23 11 2 D001 PXX2 56 224 2 D002 PXX3 666 332 ======================================================== TARGET1 2 XYZ 456 TUBE CITY2 TARGET2 2 2001 AAP1 334 443 2 2002 AAP2 44 22 TARGET3 2 D001 PXX2 56 224 2 D002 PXX3 666 332
Useful UNIX commands regular/frequently used
Suppose on 1st Nov 2010 you had created a mapping which includes huge aggregator calculations and it is under process for next two days. You will notice that even on 3rd day also its still calculating. So without changing a logic or changing a mapping How will you troubleshot or to run that mapping? Explain the steps
when we create source as oracle and target as flat file, how can i specify first row as column in flat file?
which one is better performance wise joiner or look up
How you know when to use a static cache and dynamic cache in lookup transformation?
What are the tasks that source qualifier performs?
What is the difference between power center and power mart? What is the procedure for creating independent data marts from informatica 7.1?
What is the approximate size of data warehouse?
6 Answers Accenture, i3 Solutions,
In SCD type 2 if we had select date range. then suppose we had inserted today's date(eq. date is 30 aug 2010) then start date will be today's date(30 aug 2010) what will be the end date,we cant leave it blank?
In incremental loading using Mapping variable if session failed with any of reason in the middle of process. is the Mapping variable remains constant or change?
i have source flat file like 1 a,1 b,1 c,2 a,2 b,2 c i want output as 1 a,b,c and 2 a,b,c ... how can achieve this