Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc test is replaced with hplc test. At the 4th year frequency the product is failed in hplc test .how can i assain the expiry or retest date and can i stop or continue the programme?

Answers were Sorted based on User's Feedback



stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc..

Answer / guest

The product is assigned 3 years expiry.

Is This Answer Correct ?    0 Yes 0 No

stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc..

Answer / ruchi

Please do not join ZEON lifescience paonta sahib as this company don't give offer letter and on the joining date they refused to get you in. So plz do not join this company for your better future.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

Why 1.2% KCl is used for limit of stray light? and why limit of stray light is required in UV calibration?

5 Answers   Lupin, Ranbaxy,


what is optical active and non active give examples?

1 Answers   GVK,


How to know HPLC column performance?

4 Answers   Meghmani Organics,


how require to interprit the method precision data of hptlc?

0 Answers  


How you will select the runtime in HPLC for a drug in method development.

6 Answers   Aurobindo, GVK, Lesanto Laboratories,


difference between IR & NMR spectroscopy ?

9 Answers  


what is difference between IR lamp and polarimeter lamp

2 Answers   Raks Pharma,


0.1 atom gram of the unknown element( X)reacts with 2.4 gram of O2 to produce the oxid product . can you tell us, what is the oxid formula ? a) XO b)X2O3 c)XO2 D) X2O4

1 Answers   Ajanta,


How to select buffer for HPLC mobile phase

4 Answers   Cadila, Cipla, Lupin,


why hexadecane is used in calibration of FID IN GC THERE IS NO REMAINING SOLVENTS

1 Answers   DRL, Hetero, MSN,


Which column is more polar, C8 or C18?

6 Answers   Cipla, Glenmark, Laurus, Torrent Power,


When we calculate Impurity against impurity std.solution and when we calculate impurity against diluted standard with applying RRF?

2 Answers   Torrent Pharma,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)