what is the film thickness in ftir

Answers were Sorted based on User's Feedback



what is the film thickness in ftir..

Answer / bhupalreddy

0.038 (0.04)mm

Is This Answer Correct ?    14 Yes 0 No

what is the film thickness in ftir..

Answer / amit desai

0.05mm

Is This Answer Correct ?    6 Yes 2 No

what is the film thickness in ftir..

Answer / dr. sp goswami

35µm or 0.038 near = 0.04mm polystyrene film thickness as
mentioned in EP

Is This Answer Correct ?    2 Yes 0 No

what is the film thickness in ftir..

Answer / jay

it is 35 micron as per pharmacopoia EP. IP

Is This Answer Correct ?    1 Yes 1 No

what is the film thickness in ftir..

Answer / sudhakar

i think 35µm

Is This Answer Correct ?    2 Yes 3 No

what is the film thickness in ftir..

Answer / gckreddy

0.1 mm

Is This Answer Correct ?    1 Yes 2 No

what is the film thickness in ftir..

Answer / sameer jagtap

0.05 mm polystyrene film

Is This Answer Correct ?    0 Yes 3 No

what is the film thickness in ftir..

Answer / kpr7777

analytical chemistry

Is This Answer Correct ?    0 Yes 8 No

Post New Answer

More Analytical Chemistry Interview Questions

why the same column give different retention time in hplc?

7 Answers  


how to qualify the impurity?

0 Answers  


Sulphated Ash incresed it will effect on product yield?

3 Answers   Biocon, Lupin,


give clarity of linearity and range in method validation

0 Answers  


why reference flow required during hplc analysis on rid?

1 Answers  






Why perform dissolution multimedia study in dissolution Development

4 Answers   Cipla, Optimus,


WHAT IS THE DIFFERENT BETWEEN PURITY, POTENCY AND ASSAY

6 Answers   Glochem, Hetero,


how to calculate the Step and ripple accuracy for pump gradient test for UPLC?

1 Answers   Wockhardt,


What is the requirement for brazil in the analytical method vslidation comparr to ich?

0 Answers  


stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc test is replaced with hplc test. At the 4th year frequency the product is failed in hplc test .how can i assain the expiry or retest date and can i stop or continue the programme?

2 Answers   Nakoda Chemicals,


function of detecter in hplc ,gc and spectroscopy? function of carrier gas in gc?

0 Answers   DRL,


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

0 Answers   Pfizer,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)