Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In GC and HPLC ,how we can decide which of following method
will be suitable or use for quantitation of chromatogram at
the time of method development.
1.Area Normalisation
2.External standard method
3.Internal standard method



In GC and HPLC ,how we can decide which of following method will be suitable or use for quantitati..

Answer / balaji

FOR ASSAY INTERNAL STANDARD METHOD IS GENARALY USED,IF
KNOW CHARETERISED IMPURITIES ARE AVALIBLE GO FOR EXTERNAL
STANDARD METHOD AND NO IMPURITES OR ID STANDARD IMPURITES
AVALIBLE MEANS GO FOR AREA NORMALISATION METHOD

Is This Answer Correct ?    1 Yes 3 No

Post New Answer

More Analytical Chemistry Interview Questions

Shall i use a same hplc column for two different products.?

3 Answers  


what is the meaning of stress study?

2 Answers   Reddy Labs,


what is the defination of accuracy & presicion?

8 Answers   Amneal Pharmaceuticals, GSK,


HOW TO CALCULATE THE MASS OF UNKNOWN IMPURITY IN LC-MS? AND WHAT IS THE ROLE OF FRAGMENTATION IN LC-MS ?

1 Answers  


why we use kbr as constant in the FTIR ?

4 Answers  


What is pooled sample in Dissolution

2 Answers   Graviti Pharmaceuticals, Lupin,


In pharmacopeal solibility parameter of a material, is et essential to test all paramete? If 70-75% parameter passes can we assess that the material is satisfactory or not?

1 Answers   Aurobindo,


what is a drug?

11 Answers   Aurobindo,


give me method of calculating co relation of coefficient for HPLC,SOR & ANY OTHER

1 Answers  


What is the reason for negative peak in HPLC while using UV detector.

2 Answers  


Wath is the differenc between two column HPLC wich have the samme support , lenth , pore size, etc.. But different name .for exemple : Spherisorb / lichrosorb

2 Answers   NDA,


In UV we measure absorbance , how it is happend ? explain me

4 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)