Answer / nitish
select parameter in universe go to control tab select query limit size set to 1000 or 10000 depending upon the requirement
Is This Answer Correct ? | 5 Yes | 0 No |
Answer / guest
In the report go to edit query in properties tab there ucan edit.
Is This Answer Correct ? | 5 Yes | 3 No |
Answer / tarukhemu
You can go to
Tools > Manage Security > Manage Access Restrictions > New > 'Controls' tab > Limit size of result set to
This will allow you to set the row limit for only a particular user rather than for the whole universe data(which can be done as File >Parameters >'Controls' tab)
Is This Answer Correct ? | 0 Yes | 0 No |
we can manage max no of rows in universe and reporting side.. in universe go to row level and in report goto proprties of report
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / shikha
Can anyone tell me whats the maximum no. of row limit for bex query?
Is This Answer Correct ? | 0 Yes | 0 No |
Once the project is submited to the Client. Client says that report is taking long time to run? Where u need to check?
How to execute the MACRO through Infoview?
How to add additional objects or tables into the universe,and what are steps we need to follow to achieve the above task.
how u restrict the values?to display 5 values insted of 10 values?
What is #DATASYNC error how to remove it?
Can any one gve me the complete information abt Certfication of Business Objects ?
What are templates? Explain what you have created?
Explain about a tricky situation for which you found a very simple solution?
What's the Functional & Architectural Differences between Business Objects & Web Intelligence Reports?
I have only 1 dataprovider and using that i have to create 2 tabular report on Webi on same page. One report will display all the salary details and other report will display only max salary. How will you achieve this.
I have 2 doubts regarding the "Input Control" functionality in BI4: 1) Can the Input Controls in BI4 be manipulated? I mean, can we change the IC display as BOLD or change the values from Italics to regular? Or change the colors? 2) How to get hierarchy type control in IC? Let's say my first IC is for Country and second is for State. If I select a particulat country from Ist IC,second one should show me states belonging to selected country. Is that possible? Thanks in advance!!!
Is it mandatory to give a cardinality ? If cardinality is not given what will happen?