why the LED of my electrical meter glows even after the line
has gone.
what actually the reason?

Answers were Sorted based on User's Feedback



why the LED of my electrical meter glows even after the line has gone. what actually the reason?..

Answer / praveen

as led consists of parasitic capacitance during the supply it gets charged and discharges the stored energy when supply is not there this causes led to glow for some time

Is This Answer Correct ?    3 Yes 1 No

why the LED of my electrical meter glows even after the line has gone. what actually the reason?..

Answer / ghanshyam singh

but Mr. praveen, the led glows for a long time, often more
than one hour, and this is also rare i.e it does not happens
all time that led glows. sometime it turns off with the
supply.

Is This Answer Correct ?    0 Yes 0 No

why the LED of my electrical meter glows even after the line has gone. what actually the reason?..

Answer / ghanshyam singh

i think it's due to the leakage current/ flux.

Is This Answer Correct ?    1 Yes 7 No

Post New Answer

More Electrical Engineering Interview Questions

Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?

0 Answers  


which model T or pie model is prefarable in power syatem

0 Answers  


how to find insulation resistance of a motor(415v) by theoretical formula??

2 Answers  


what are types of servo motors

1 Answers  


we all know that both the generator and motor are electromechanical conversion devices.....then why we rate motor in kw and generator in kva????

4 Answers   KSEB,






What is the minimum value of hfe for the oscillations in transistorized rc phase shift oscillator?

0 Answers  


As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.

0 Answers  


What is delta stare switch?

1 Answers   Samsung,


What is the use of core in the transformer?

19 Answers  


where we use 1 phase & 3 phase supply ?what is major advantage using 3 phase over than single phase ?

3 Answers  


What should the transformer connection of a 11/220 kV step up and 66/11 kV step down transformer ?

4 Answers   CGL,


1.what is bus cuplour and main funtions. 2.what is main function of alternator. 3.how many types of dg oils.

11 Answers   Bhel,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)