Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Who we calculate the generator NGR resistant, generator
voltage 11 KV ?

Answers were Sorted based on User's Feedback



Who we calculate the generator NGR resistant, generator voltage 11 KV ?..

Answer / k.prakashchandra

generally = phase voltage/full load current

Is This Answer Correct ?    3 Yes 0 No

Who we calculate the generator NGR resistant, generator voltage 11 KV ?..

Answer / iqbalaam

generation type

Is This Answer Correct ?    0 Yes 3 No

Post New Answer

More Electrical Engineering Interview Questions

Hello sir This is prakash from bangalore i have a doubt why we have to maintain DG power factor in the range 0.78 to 0.8 Perhaps i f it is increased means what will happen in DG

3 Answers  


if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .

0 Answers   BSNL,


The unit of electrical charge is the

1 Answers  


Abb 11kv how it is closing automatically when the cb is racking in and rack out when it reaching test position

1 Answers  


Why ELCB trip, when neutral touch with ground?

1 Answers  


why cant we use earth as neutral at home whereas neutral is actually grounded at transformer end?

4 Answers  


How can we calculate cable size in Low voltage & high voltage

0 Answers   United Breweries UB,


what is working of communitator in a dc generator?

3 Answers  


What is the arc. I saw word arc in between sf6 & vcb brakers

1 Answers   Cap Gemini,


explain why the armature voltage changes when the field rheostat is varied in self excited DC generator

2 Answers  


why the rating of dc generator is in kw where as rating of alternator is in kva?

3 Answers  


What is the multiplying factor if line ct ratio is 1000/1 and meter ct ratio is -/5 ?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)