why does the result variation in hplc and gc with same
sample ?

Answers were Sorted based on User's Feedback



why does the result variation in hplc and gc with same sample ?..

Answer / dinesh

hplc is adsorption chromatography, in HPLC we have separate the compounds based on adsorption technique
but GC is working based on evaporation technique so the variation coms out..............

Is This Answer Correct ?    19 Yes 1 No

why does the result variation in hplc and gc with same sample ?..

Answer / gokul yeole (archpharmalabs)

Both techniques are sepration based, hplc is adsorption
chromatography, in HPLC we have separate the compounds
based on adsorption technique.
in GC is working based on evaporation technique usig gas as
crrier so the variation coms out.

Is This Answer Correct ?    2 Yes 0 No

why does the result variation in hplc and gc with same sample ?..

Answer / malyadri

Hplc is a adsorption chromatography ' we have elute the chromophoric nature and non volatile samples are suitable for hplc. Non volatile compounds are not suitable
GC analysis volatile nature compounds are suitable.

Is This Answer Correct ?    2 Yes 0 No

why does the result variation in hplc and gc with same sample ?..

Answer / chennusrinivas

Simple logic principle diff for both.

Is This Answer Correct ?    2 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

why we are use metthanol variously in kfr?why don't use other solutions?

4 Answers  


difference between calibration and validation

2 Answers   Mylan,


why are using toluene in uv calibraion in resolution performance

2 Answers   MSN Pharma,


How do you show that equal quanitities of two isomers provide the same response using a PDA

1 Answers  


What is the principle of GC/HPLC ?

4 Answers   BioCan, Biocon, Megafine Pharma,






how std. of znso4

1 Answers  


if you given one product then which tests you will perform?

0 Answers  


What is the difference between chromatographic purity and related substances?

0 Answers  


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

0 Answers  


In Agilent HPLC calibration using Empower 3 Software, What is the criteria for GPV Baseline starting point? i.e., Either it can start from -0.00/+0.00 or any range is there like -0.05 to +0.05 or ......etc?

1 Answers   Apotex,


why we use prednisone tablet in chemical callibration of dissolution apparatus?

6 Answers   Cipla, Mylan, Umedica Laboratories,


why we use caffeine for hplc calibration?

5 Answers   Aurobindo,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)