Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why does the result variation in hplc and gc with same
sample ?

Answer Posted / malyadri

Hplc is a adsorption chromatography ' we have elute the chromophoric nature and non volatile samples are suitable for hplc. Non volatile compounds are not suitable
GC analysis volatile nature compounds are suitable.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1800


How to know the estimated LOQ concentration in ppm

1153


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2175


What is the formula for relative diffrence for standard solution in solution stability in validation?

737


why require to add enzymes in capsules dissolution only? is it require to tablet also?

640


acceptance criteria for lod & loq by standard deviation of response and slope??

2531


why holium oxide prepared in 10% HCLO4 SOLUTION

1403


Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18

1854


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1906


pharma industries oriented

2172


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3116


in which situation ion pair require to use?

742


what is mean by peak intigrity?

860


how you determine moist.of NaOH sol or NaOH flacks

2173


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

765