why clock frequency of microcontroller 8051 is chosen as
11.0592 MHZ?
Answers were Sorted based on User's Feedback
Answer / abhishek
for making serial port of 8051 compatible with IBM pc baud rates
Is This Answer Correct ? | 45 Yes | 8 No |
Answer / s md rafi
bcoz that is the one frequncy that is divisible by the standard baud rates...,
Is This Answer Correct ? | 23 Yes | 4 No |
Answer / ali gachkar
By using an eight bit divider we get
11.0592Mhz / 128 = 86400
and Day is (24 * 60 * 60 second ) equal to 86400
By using an eight bit divider and divider to 10 like 4017 we get 86400 from 1.8432Mhz
by using these to Xtal (11.0592,1.8432) we get the standard baud rates
75bps Base (The V.23 standard) https://en.wikipedia.org/wiki/ITU_V.23
multiplier 1.5 and 2
150,300,600,1200,2400,4800,7200,9600,14400,21600,28800,.....
Is This Answer Correct ? | 1 Yes | 0 No |
Answer / manoj kumar pradhan
Since a machine cycle consists of 12 oscillator periods,the
count rate is 1/12 of the oscillator frequency.so 12 MHZ is
used for it.
Is This Answer Correct ? | 12 Yes | 16 No |
Answer / ashok
in 8051 each machine cycle have 12 clock cycles. it maximum
operates in 40MHZ.
Is This Answer Correct ? | 18 Yes | 33 No |
Why is modification of signal required for transmission Over channel?
How is focussing achieved?
i am fresher for giving intervivew in it sector and also sales electronics. all about related qustions send me please?
What is meant a series inverter?
Draw the circuit diagram of 1φ auto sequential commutated current source inverter and explain its operation with equivalent circuits for different modes and necessary waveforms?
What ODU work?
How micro processor works without internal memory?
What is the difference between <stdio.h> and "stdio.h"?
WHAT IS THE ADVANTAGES AND DISADVANTAGES OF CMOS INVERTER?
Explain at what voltage does land line telephone operate?
what is the relation between power and frequncy
Explain how to convert design gray to binary code?