why pegging is required for deaerator in power plant nd why
maintain the constant pressure in deaerator 3.5 kg/cm2.
Answers were Sorted based on User's Feedback
Answer / salil agarwal, power engineer
basically the pegging steam is used to create a scrubbing action between the steam and the feedwater, by which we can eliminate the dissolved corrosive gases mainly oxygen, co2, and ammonia which becomes corrosive at elevated temperatures.
The removal of these gases is necessary to protect the piping and associated equipments.
The gases removed are vented out of the D/A to atmosphere
Is This Answer Correct ? | 62 Yes | 14 No |
Answer / alex
Pegging steam is given in a deaerator to stabilize pressure fluctuations during start up/ ramp up/down conditions. Sudden pressure drop in the deaerator due to conditions like safety valve lifting can cause steaming of water in the BFP suction line. Pegging steam line is given to prevent this condition.
Is This Answer Correct ? | 5 Yes | 1 No |
assemblies in .net
write a program to print only the largest number between elements of an 1-d array?
what is networking
What is the distance between earthing pit and equipment?
What type of questions are asked in interview?
how many gallon in one quseka
what is the significance of partial derivatives.
what size shaft is required to transmit 100 hp @1000 RPM ,if max shear stress is 10,000 PSI,angle of twist must be less than 1' /ft/shaft is made of steel.
What is the full forms SDDC,TOR,DLRO,PPP,USW,AWWA,CMOS,SVI,
plz explain abt refrigeration r22 bitzer comprassors trouble shooting and maintenance
. Give the C language equivalents of the following a)Function returning an int pointer b)Function pointer returning an int pointer c)Function pointer returning an array of integers d)Array of function pointer returning an array of integers
I have Job A and Job B in jcl. I want to trigger Job B from Job A. Please advise.