in an industrical wiring, why we are using lighting DB and
Power DB separately?

Answers were Sorted based on User's Feedback



in an industrical wiring, why we are using lighting DB and Power DB separately?..

Answer / saravanan.p

In an industries, they are using different load. If we are
using single DB for lighting and power means, the variation
of load when we are using will affect the input voltage.

The lighting load is the uniform load and small. But the
power load will varry according the usage. For better
maintanence both DB's are provide separately and providing
the separate size of input cables.

Is This Answer Correct ?    10 Yes 0 No

in an industrical wiring, why we are using lighting DB and Power DB separately?..

Answer / lijesh p k

In an industry,various loads are used for various
purposes.Lighting loads are usually small and UNIFORM.But
in the case power loads they vary as per the usage which
may affect the input voltage.So to safeguard against faults
and for easy maintenance different DB's are used for
lihgting and power in industrial wiring.

Is This Answer Correct ?    6 Yes 0 No

in an industrical wiring, why we are using lighting DB and Power DB separately?..

Answer / bidesh biswas

TO MAKE AN ELECTRICAL ISOLATION BUT TO MAKE MAGNETICALLY
COUPLED THROUGH 1:1 (APPROX) LIGHTING TRANSFORMER.

Is This Answer Correct ?    1 Yes 3 No

Post New Answer

More Electrical Engineering Interview Questions

what are the safety measures of induction motor?

0 Answers  


What is thyristor?

13 Answers  


why we are using panel space heaters in different control schemes????

3 Answers   Mecon,


Whot is the braking capacity for MCCB. How we select different braking capacity.

1 Answers  


If carbon brushes spring tension either loose or tight, what happen on Motor performance During Full load Operation?

5 Answers   Electrex, HP, TATA,






we often use the word HT (high tension) line.or we say HT switch gear, whats does HT basically mean. is it different from high voltage.

1 Answers  


Why the symbol of register is "zig zag"

0 Answers   Suzlon,


How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?

0 Answers  


Alternator couple to diesel engine why, Alternator couple to ac service motor with gear drive for 1500 rpm possible (yes or no) aim to low input power supply give to motor then high output power taken for alternator Please answer this question

1 Answers   Turbo,


Why Phase to Neutral get spark

2 Answers  


show that power dissipated by a pure inductor exited by a sinusoidal voltage source v = vm sin wt is zero

1 Answers  


what is meant by 3rd hormonics ?

0 Answers   VRVS,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)