Upto what presrure natural circulation is possible in Boilers?.
Answers were Sorted based on User's Feedback
Answer / jeba
upto 150 ksc natural circulation is possible,upto 175 ksc
assisted circulation is possible(pump),above 225ksc forced
circulation is possible
| Is This Answer Correct ? | 2 Yes | 0 No |
Answer / devanesan
below the critical pressure of the liquid(water).
| Is This Answer Correct ? | 1 Yes | 0 No |
Which questions will be asked for mechanical design Engineer position in GE?? plz give me reply it's urgent...
At 50 Centigrade (Diesel oil) what is its cast?
i am interasted on mechanical engineer plz send any mechanical engineer book for my emailid:-dyagnesh22@yahoo.com
Are mechanical seals in pumps direction specified?
what is the working principle of a vibration meter?
what is machnical interlock? explain the uses.
Define pitting.
Cam,Connecting Rod,Piston & Cylinders Combinely forms How many links ?
What is cutt off ratio in IC Engines.give proper defination.
5 Answers Essar, Hyundai, Jindal Steel and Power, L&T,
how to calculate cg of transformer
what is the function of a pt pump of a dg set
What are you going to inspect or check when you open the crankcase?
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)