Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

VECL,

2512

Can a generator rated 400 V, 60 Hz be used in a 50 Hz System? Yes or No ? Why ?

VECL,

1 2370

What is meant by load angle of an alternator? Upon what factors does the load angle depend?

VECL,

3004

How do the synchronizing lamps indicate the correctness of phase sequence between existing and incoming alternators?

VECL,

2181

which of the following motors is non-self starting?

SS Solutions,

3 4734

We have 11kV/110V three phase indoor potential transformer in 66/11kV Sub-station, where the failure of PT is frequently happening and the rating of the PT is 0.2 class accuracy, with primary star and seconday (two cores) star connected. Some experts has suggested to not to connect the PT Primary neutral to the ground because when transformer neutal NCT connection is loose; the faulty current will flow through the PT primary neutral, resulting into failure of PT. My question is: Is it necessary to remove the primary neutral connection of the PT from ground? if not, what would be the reason for failure of PT. Please guide me.

KPTCL,

2 3752

how a circuit breakers work at fault condition .plz give a specified answer.

Regen Powertech,

1 2865

What is industrial plc

TCS,

1823

i am getting to neutral earth voltage zero ,is this a perfect earthing ?

3 4418

How we can defined theecopper cable size if we know the aluminium cable size?

Cummins,

1876

what is effect of length of air gap on performance of dc motor and generator?

DEI,

1887

How much ph is maintained of water electrolyte which is used in LRS for 1200 kw slipring induction motor ?

AMS, JK Lakshmi Cement,

1769

how to select fuse rating for a 3-phase motor ???

1802

why the power factor of the induction motor is low?

1 2481

why we don't use earthing as neutral?

1 3513


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How to configure the drives in PLC, through Profibus commnication. And to how to address it?

2838


i have completed deee and i've (June2012-feb 2015 experience in electrical maintenance in pvt ltd company.company having HT & LT electrical power.how to apply electrical C-license ,NOW I was resigned my job,what are requirements of applying for c-license

1731


Whata are the types of Cables?

2157


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1947


Why GRR starts from 60% of motor speed why not less than 60%?

1702


What is meant by vector group

2541


what is per unit calculation?looking for simple and strong explanation thk u

2565


What is the difference between rulling span and wind span of of an Over Head Transmission Line?

2325


what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....

1947


how ct burden,magnetising current,ratio and knee point voltage are related & derived

2197


How to Prepare preventive maintenance shedule of machine tool.

2021


Why phase sequence must be same in any ht motor or generator circuit?if phase sequence doesn't same whatever will be affect on circuit?

2205


How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?

1921


pls tell us AC plant are how do work and parts name with picture

1968


given data are load current & power factor cable core size? plz any one update the calculation formula

1895