1 4268how we calculate electricity unit ( meter unit.. for knowing how many charges) from on motor load.?
2 3179A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.
VECL,
2593With a phasor diagram show the effect of increasing the field current of a generator supplying a constant real power and connected to a grid system.
VECL,
1976Draw the wave shape of armature current in a generator subjected to a sudden three phase short- circuit at its terminals. Define various reactance of generator from this wave shape.
VECL,
2225A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.
VECL,
1920A generating system will have a total capacity of 300 MW. Find the probable forced outage when the capacity is supplied by two 150 MW units. The operating probability of all units is P=0.98 and forced outage probability rate Q =0.02 .
2637Post New Electrical Engineering Questions
Give details of your interested designation, the post you are interested to serve the company better and explain why you think you can serve the company better in such position if employed?
TRANSFORMERS WITH DC SUPPLY
Can you explain about TEE protection scheme?
what is working process of star delta controlling circuit ?
-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.
what transformer we used normally and upto which kva?
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
What is the formula for calculating no-load current?
why the value of k is more in shell typr transformers?
What is the unit of charge and current?
how balanced in star delta connection ?
How to discuss the phase shift of transformer considering open delta?
what will happen if OLR CT in all phases are short circuted
how does high earth to neutral voltage affect electronic equipment?
How 48-relay (incomplete sequence) functions?