Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Batteries used for electrical energy storage are a. Laclanche cells b. Edison cells c. Lead acid cells d.any of the above

1907

A circuit breaker on detecting fault will a. Open b. Close c. Open and trigger the alarm

2 3481

If we have two nodes A and B and Vab is the potential difference between these nodes then which node is called reference node a.node A b.node B c. Ground node

1 5737

To have variable speeds we use a. Induction motor b. Traction motor c. Shunt motor

1 3245

ROC converges if poles and zeros lie inside a. Origion b. Z=1

2260

Period of infinite continuous fourier series a. N b. N+M c.infinite

1 5379

Which protection detects both AC and DC?

Megatron Solutions,

3 6239

how to calculate total load in a villa?

Megatron Solutions,

1 3710

In Single Phase AC Supply,If Voltage between Phase and Neutral is 230V means what will be the Voltage between Phase and Earth?

2 3574

best manufacturer for busbar for outdoor switchyard having double bus bar scheme, can any one share technical specification of busbar. 132kv voltage ?

1716

I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1752

We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.

SK Engineering,

1660

Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.

SK Engineering,

1765

How to calculate the size of earth cable to earth the neutral of UPS ?

N Johnson,

1937

how many ht 11 kv cable size for 11kv 2000 kva 11kv*433v transformer ?

Megatron Solutions, TCS,

3 8890


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What are the advantages of stationary armature and rotating field system?

1226


A system absorbs 100 k J of heat and the increase in its internal energy is 100 kJ; the work done is

1282


what is the effect of power factor of machines in starting current

2055


How to calculate the no of Ceiling fan (1200mm sweep) per unit area?

2079


What is given by the definition in BIL IMP/PF = 950/395 kV. This was found in a name plate of a power transformer.

2357


sugest any typical project ?

1819


How many energy meters can be connected on a 15VA Voltage transformer. please send a calculation sheet.

1943


in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain

1857


Why can't we take NO LOAD TRIAL of motors having V1 mounting??

1926


What type of a DC motor would you use for a lift?

1077


what is transistors comprised of?

1179


What is capacitance?

1231


whatare the disadvantages occur,if the form factor of transmission will not be equal to 1.11

1866


Difference between low impedance and high impedance Restricted Earth Fault

3123


How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9

2161