Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

What is basic difference between Soft Starters And VFD drives?

IBM,

19 51332

Between Star-Delta & Star-Star Power transformer which one is efficent for Earth Fault?

10 16671

Why we are use 11KV / 22KV / 33KV / 66KV / 110KV / 230KV / 440KV this type of ratio. why cant we use other voltage ratio like 54KV / 99KV et.,

College School Exams Tests, Hino, ITC Infotech, Reliance, UPRVUNL,

8 31792

From the point of view of accuracy in the Measurement of Electrical energy should we select a potential transformer or a capacitor voltage transformers?.Kindly support your reply with reason and justification.

1 3891

HOW DOES ONE SELECT A TRANSFORMER PHASOR GROUP IE, WHETHER A STAR-DELTA TR OR A STAR-STAR OR A DELTA-DELTA, ETC. TRANSFORMER IS MORE SUITABLE FOR A PARTICULAR KIND OF LOAD OR WORKING CONDITION???

KPTCL,

3 7666

What is the secondry voltage of 420kV Current Transformer , the rated current is 2600A

6 8046

1. what is the power factor and whatis his losses 2. what is the working procedure of 51RNB AND 87 relay

ABB,

3 6231

What is the difference between RMS and average value

CEERI, HPCL,

5 38196

When geneartor is running in poor lagging side power factor its excitation current increases then it is running in improved lagging side.Kindly tell me when gen is running in leading side what will happen

3 6575

Can any body tell me about Hi-pot test, and why it is necessary and its procedure of testing

6 9698

Can any body tell me about partial discharge test, and why it is necessary and its procedure

1 4400

Why not implimenting power factor in Diesel generator

HP,

6 10926

how vfd drives energy save

PowerTech,

5 10333

in slip ring motor if motor specification is given how we calculate its rotor resistance in starting

1 4891

If single phase voltage level is 230V than why three phase voltage level is not 660V ?, but it is only 440V.

BSNL, DOS, EFS, HMT, L&T, TCS, ThyssenKrupp,

16 74592


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

WHAT IS MEANT BY TV TERMINAL IN 500MVA TRANSFORMER?

2210


how do prepare ongc exam.how is it question model.i am electrical. which part covering in electrical.tell me

2221


How will polarity test of Dy5 Transformer ?

2221


Do inductive loads have distorted current waveforms ?

1876


What is measurement?

1139


which type of questions asking for solar companies?

1540


what is the common earth

1035


hai iam arunkumar. i have applied for an section enginner in rrb. i want lat 5 years solved question papers. if u have please sedn it to arun30682@gmail.com

1776


Why the arms of delta in a delta-wye power transmission system are kept constant??

1834


how the testing of protection CT Testing done through Primary injection kit please describe in detail procedure...

2180


explain why core loss of a transformer is almost constant under different load conditions when connected across a constant voltage and constant frequency.

2657


Why syn. Generators are used for the production of electricity?

1103


what do you mean by type zero control sytem ?Give an practical example of type zero contol sytem?

1917


what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?

1870


WHAT IS AIR GAP VALUE IN MM FOR A 11KV BUSHING OF 11KV/440V DISTRIBUTION TRANSFORMER. AND AIR GAP VALUE OF 25 KV BUSHING OF AT TRANSFORMER OF 25 KV TRACTION. WHAT IS THE CALCULATION FOR THE AIR GAP PERMITTED FOR BUSHINGS AT DIFFERENT VOLTAGES.

3442