Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

what do you mean by earth fault in transformer?

L&T, UPL,

2 17601

In a HT switchboard where Nos. of Transformers are connected, how to decide Incoming cable size? Whether Cable should be rated for connected load or maximum demand?

Power Grid,

1 6187

why two windings are using in single phase AC motor

3 9105

define power quality

1 4564

difference between alternator & GENERATOR

4 8305

exact difference between electronicsand electrical

5 6690

Please explain me about Relay curves and their sources to read ?

1769

How generating electric power export to grid from the generating station ?

1826

what is the conductor size in 33/11 kv line

Al-Thamer,

5 24645

WHaT IS THE CONCEPT OF INDUCTION LAMPS IN MODERN LIGHTINGS, and HOW IT WORKS TO EMIT LIGHT ( AS NO ELECTRODES ARE PRESENT ) ?" COULD INDUCTION LAMPS CAUSE INTERFERENCE WITH COMUNICATIONS INTO A STORE USING INDUCTION LIGHTING ? WHAT IS THE BENEFIT OF USING THE LOW FREQENCY INDUCTION LAMP , VERSUS LED , AND VERSUS FLUORESCENT, AND VERSUS ANOTHER KIND OF LIGHTING . THANK yOU MOISES GUINDI

2042

why there is a humming noise in transformer

Bhel,

8 11519

why we use the fuse in only one wire? althrough in ac current the current flows in both directions. why the neutral wire can be taken half the magnitude of phase wire while same current returns from neutral wire?

Bhel,

2 5058

how is reactive power controlled on the transmission system

2 4484

Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?

1716

what are corona losses

Siemens,

3 6570


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Bimetal strip used in overload relay what is that,which types of material used for that & percentage.

2157


i want wipro vlsi placement pattern please send me

1733


How eddy current generation support the idea of train braking?

1942


What are the characteristics of negative feedback?

1021


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1868


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1825


explain why core loss of a transformer is almost constant under different load conditions when connected across a constant voltage and constant frequency.

2657


harmonics filter

1905


difference between ac series and parallel circuit

1990


what is the size of cable for 15kw motor and 85 meter cable length using with vfd

2319


If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.

1396


what is maxemo work permit procedure

2164


How to calculate multiplying factor of dc energy meter

1621


What does quality factor depend on in resonance?

1042


Refernce currents are to be generated using refernce cueernts how can this be done??

1964