why EMF IS INDUCED IN A CONDUCTOR WHEN FLUX LINKING WITH IT CHANGES ACCORDING TO FARADAYS LAW.
Sail,
1983what is the principle to generate energy from water or coal, plz define the step by step how & when electricity energy start from resource area to ours home meter & separate & how meter read the voltage or current?
1 3343What does OHB stand for in specifications for circuit breakers, especially found in SF6 circuit breaker?
1 6043IN SOME CASE, WHEN I GIVE 24VOLTS DC AS INPUT, WHILE IN OUTPUT (THAT MEANS TERMINAL SIDE OF THE INSRUMENTS) I,M RECEIVING ONLY 6 VOLTS, WHAT IS THE REASON FOR THAT MUCH VOLTAGE DROP?
3 5105HOW THE AC GENARATOR CAN GENARATE REACTIVE POWER,HOW CAN WE CONTROL IT.AND OTHER SOURSES OF REACTIVE POWER GENARATIONS ARE WHAT.
3 5358DOES AN EARTH FAULT CURRENT ON THE DELTA SIDE OF A 6.6/33KV STEP UP STAR-DELTA CONNECTED TRANSFORMER REFLECT ON THE STAR SIDE? IF YES, THEN HOW AND WHAT IS THE AMOUNT OF CURRENT REFLECTED?
1 5246Post New Electrical Engineering Questions
what is your aim
1. what is usage for power factor in industries?? 2.why we need to monitor power factor??
I want to calculate how much capacitor we connect to maintain the unity power factor? Is there any formula? Pls give me the answer
acb(AIR CIRCUIT BREAKER)NOT CHARGING AUTO
What is the difference between Encoder and Resolver?
Define ampere
3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.
WHAT IS MEANING OF Gg & Gg IN hrc FUSE
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
How can we connect additional batteries to three phase ups? What are parameters we have to check when connecting?
How do i carry out or know the vector group of a Dyn1 and Dyn5 transformer
Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.
Write masons gain formula.
why ht cable end termination don't have a gland?