I WANT YHE TECHNICAL AND ELECTRICAL SPECIFICATIONS OF 2x4MW 11KV 2x10MW 11KV 2x25MW 11KV 2x100MW 11KV HYDEL POWER PLANT i.e PROTECTION SYSTEM,MONITORING,CONTROL SYSTEM,GENERATION,SYNCHRONISATION,METERING PLEASE SEND THE DETAILS TO MY MAIL ID SPRAVEEN_222@YAHOO.CO.IN
1652Can 4pole (3 phase+neautral )RCCB proper functioning in only 3 phase load (no neautral, no Earth) ?
1697how can we decide where we have to DYn11 or other vector group transformer
BSL, Knight Frank, Security Printing and Minting Corporation of India Limited,
4 30415What is polarisation index value?.(pi value) Simple & brief definition of polarisation index?..
7 17089Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB
2287explain how the power is distributed from a power plant to a consumer.explain step wise in detail
1 3565what r substations?what r there work?why voltages r incresed and then reduced during distribution of power
1457The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason
1933* Signal transmission in sky wave propagation is due to ? a) Reforction of wave b) Reflection of wave c) Pierus through Inosphere d) None and Reason for this is????
2 5116Post New Electrical Engineering Questions
can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you
upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.
How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.
Is there chopping current in resistive circuit
What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.
draw a circuit diagram connecting transformer OLTC- RTCC- VCB-Marshalling Box otherwise Explain in words
What is the basis for framing the rules of block diagram reduction technique?
How to work meggar?
What is difference between unity power factor wattmeter and upper power factor wattmeter? In short circuit test of transformer the wattmeter used is unity power factor type or upper power factor type wattmeter?
how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?
what will be the effect if you were using different brands of outlets?
what is parellel power factor correction?
what will be project cost for 100 kv transformer connection under oyt scheme.
Can any body tell me the different types of LT cables & their application.
how is the incoming cable size calculated for a given current rating of a panel??