Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2 6323

WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?

ABB, Nissi Engineering Solution, NSL Sugars,

5 25656

what is the function of CRGO in a Transformer?

6 11263

what happens when a DC supply is given to AC motor?

Areva, ISMT,

9 24873

what is the difference between elcb,rccb,mcb.

HCL, RCCB,

8 41871

I have a shop heater with a 1/3 hp capacitor start, induction motor driving the fan. Intermittently, the fan motor speeds up significantly for several seconds (15-60 sec) then slows to normal operating speed. The manufacturer suggested changing the capacitor which made no sense, but I did it to no avail. Could this possibly be caused by the centrifugal switch intermittently reconnecting the start winding?

1 3717

how we masure a cuurrent?

5 7063

when we increased the current what do ?

2023

how we calculate the dick for a pole?

Power Grid,

2144

name the types of insulatter?

5 8565

what is the principal of star delta starter?

9 46675

HOW TO BUILD THE SINGLE PHASE TO THREE PHASE CONVERTER? CAN PROVIDE ME CIRCUIT..THANKS

2081

I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

Jindal,

2236

Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

Accenture,

2011

How to calculate the current rating of power cables ?

1 6461


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What is Antipumping Function & If we have C.T how we find the Ratio ?

1982


How to test the Secure Elite 440 Multi function meter working condition.

2112


What is difference between SMC supportg and Glass Fibre Reinforced Plastic Support.

2302


what is servo motor and how to work it.

1871


how to select rating of HT Panel

1408


What will happen if the voltage in my house drops from 220V to any lower voltage?

2135


how to select overload-relay for perticular motor 1.for D.O.L. starter 2. for Star-delta starter ????

2796


from where the self excitrd induction generator get the power?why is the voltage regulation is poor of seig?

2217


An active element is one which a. Supplies energy b. Absorbs energy c. Supplies energy and convert energy from one form to another

2023


Compare jfet’s and mosfet’s.

1226


how can maintain the power factor and why and this is how do work tell us

2047


what is the minimum voltage require to injure our body?

6774


hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?

2044


what is class of SPD and dittels of all class ?

2067


what is meant by directional earth fault and non directional earth fault? describe both.

1854