I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
2 5409WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?
5 23789I have a shop heater with a 1/3 hp capacitor start, induction motor driving the fan. Intermittently, the fan motor speeds up significantly for several seconds (15-60 sec) then slows to normal operating speed. The manufacturer suggested changing the capacitor which made no sense, but I did it to no avail. Could this possibly be caused by the centrifugal switch intermittently reconnecting the start winding?
1 2770I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
1843Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?
1591Post New Electrical Engineering Questions
can any one tell me about the Extra low voltage systems?From where we give supply to these type of systems??
Differentiate between digital phase converter and ordinary phase converter.
How to know the Max. current caring capacity of the cable by its size ?
what do you mean by every IC 74 first digit.why are you using this no.why not using another no.
power transmission pole used one support , that only for support or earthing
How you calculate the repturing capacity of a HRC fuse
what things to be considered when designing UPS
how is the incoming cable size calculated for a given current rating of a panel??
1.What is captive power plant? 2.What is national grid?Give brief idea.
how is the connection of a 3 phase ct trivector meter done on a pole mounted transformer
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
what are the analog quality input for protection function?what are minimum reqiments?
What are the functions of temperature scanner in power transformer?
Why can't we take NO LOAD TRIAL of motors having V1 mounting??
How to checked frequency drive output voltages?