Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

what is the hearth and arch pressure in furnace?

IFFCO,

4058

what is the hearth and arch pressure in furnace?

Essar, TATA,

4907

#include int main() { char *ptr; char string[] = "How are you?"; ptr = string; ptr += 4; printf("%s",ptr); return 0; }

Wipro, Zoho,

5 24322

What is the formula that shows relationship between voltage and speed in an induction motor

2 5181

i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula

May Baker,

2209

How to calculate carrying capacity of the existing water supply trunkmain

2289

What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?

Jubilant,

3461

what diffrence b/w plc s7200,300,400

IFFCO, Reliance,

2070

show the single line diagram of star delta starter with single phase preventer

4641

please help me i want that steel bar weight kg/foot if anyone have formula so tell me .

3 7587

What safety followup during kWh meter isolation

2102

why we use conio.h in c programming?

TCS,

2110

what are the things that can cause a three phase motor to crawl?

1 3567

Steel calculation formala for column,beam and slab.

Coastal Projects,

1 8653

what type offoundation suitable for clayey type soil

2 5490


Un-Answered Questions { Engineering }

bus bar design conditions and sizing pls tell me quickly

1898


what is the need of rectifier?

1929


how we findout a ignater is faulty or not?

2108


What is wet corrosion and galvanic corrosion?

1137


What is milivolt dop test in Busducts? What is its significance & procedure to do the test?

2094


what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer

2109


How would you increase the volume efficiency of centrifugal pump?

1929


State the different types of flip flop and their uses?

1096


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1985


how to revers the direction of single phase motor

961


what is mathed of check the D.C MOTOR 181 KW (ARMATURE AND FIELD) WHAT IS THE MATHED OF CHECK THE THYRISTOR MODULE (HIGH CURRENT)

2037


Describe the sections included in a typical bill of quantities

2277


Design a cantilever slab to carry a live load of 2000 N/m2. The overhang of the slab is 1.20m. b) A slab over a room is 4.75m x 4.75m. The edges of the slab are simply supported and the corners are not held down. The live load an the slab is 300 Kg/m2. The slab has a bearing of 15cm. On the supporting walls. Design the slab as per Rankine - Grashoff theory. Assume weight of R.C.C. = 2400 Kg/m2.

2859


what are control system components?

1922


Which purpose we use deck anchor in bridges?

1098