Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

i set electrode to 7 buffer than i used it to check 4 buffer and 10 buffer if the results are not as expected than is it better to set the buffer again to 4 buffer or is there any other method available please let me know ...

Glochem,

2 7234

How much is the standard area for glc analysis

2331

function of detecter in hplc ,gc and spectroscopy? function of carrier gas in gc?

DRL,

2721

what type of compounds do we see lod @ wat type compounds do we see m.c

Orchid,

3 9621

How can the GC or HPLC method is selected to determine the impurity profile in drug product?

Ajanta,

1 7676

How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

Cipla, Rampex Labs,

4371

What the difference in loss on drying and residue on ignition

2 35323

Why irmoisture balance is used for corrugated box moisture testing

Leiutis, Lupin,

2451

why we are used 4,7,9,2 buffers for the ph calibration

Aurobindo, Enaltec Labs,

4 19782

In case of HPLC coloums what is the difference Between C8 & C18 coloums & how can we select difference type of coloums like Inertial ODS , Hypersil BDS , ODS etc.?

MSN Pharma,

4 33571

Is sonication essential in solubility testing of a drug substance?

Aurobindo,

6 16932

what is different between volumetric solution and general solution

1 18926

what is primary solution and secondary solution

2 8551

what is RI detector Cut-off Value

Mylan,

1 10098

In Related Substances Test how we can reside the limit of impurity ?

MSN Pharma,

2 11512


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

What is Band broading effect explain

1941


what is mean by extactable and leachable study?

1226


What is diffrence between extractable volume and deliverable volume? Answer pls

4619


How to do regeneration of Metacarb Pb plus column?

2610


why multimedia dissolution require to do?

867


Why we check moisture,ash & AIA in product

1942


WHAT IS THE USE OF STARTER ?????????

2472


what you do when compound having dwel wavelength?

806


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2630


what is partion and column chromatography

2468


what is third integration

2032


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

4371


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

2016


which situation gc hs and gc als require to use?

838


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

2071