Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Chemistry Interview Questions
Questions Answers Views Company eMail

Which is the highly polar and highly non polar column in HPLC?

2352

What is the difference between qualitative and quantitative analysis (hplc)

1 4636

What is the composition of Barford Reagent?

TPS,

2191

what is the difference between potentiometric titration and karl fischer titration?

3266

How NMR spectra can be calibrated in presence or absence of TMS?

1 2943

What is Michael addition?

Gharda Chemicals Limited,

1 3164

How will you determine OH of organic compound ?

Gharda Chemicals Limited,

1 2526

why is mgcl used in edta titration

1680

What is Band broading effect explain

Dr Reddys,

1944

Active Ingredients in septilin ??

1761

we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

Cipla,

1928

tell me about aliphatic acid estimation by hplc which columns can we use

Dr Reddys,

1 3656

does water content by KF will calculate only external moisture absorbed or the ligand ? (for ex copper sulphate pentahydrate)

NA,

1976

Why we perform the ir analysis?

Sequent,

3 5173

difference between calibration and validation

Mylan,

2 5163


Un-Answered Questions { Chemistry }

What is mineral water?

1122


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1928


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1693


what are the differences between assay procedures and estimation in chemical analysis? also what is the equivalent factor that we consider in assay analytical procedures?

2731


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1970


What is the reaction that occurs between iodine and sodium thiosulphate?

1102


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

786


How to decide assay range for non pharmacopeial API analysis by HPLC? Could you give me any reference for same e.g Guidelines or Paper publications?

3405


How are the waters classified based on the degree of hardness?

1192


How many moles of sodium hydrogen phosphate can be prepared from 3 mol of sodium hydroxide and phosphoric acid?

2447


What is the composition of Barford Reagent?

2191


what is mean by dissolution hydrodynamics?

893


which situation gc hs and gc als require to use?

842


hi, i want last 10 years ongc exam recruitment papers for subject in chemistry ,genaralknowladge.

2861


acceptance criteria for lod & loq by standard deviation of response and slope??

2646