Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Chemistry Interview Questions
Questions Answers Views Company eMail

How to caluclate %w/v& %w/w ple give examples solids&liquids 10%NAOH W/W 10%W/V- 20%HCL W/W &W/V

Natco,

2503

why all liquid raw materials fallows residue on evaporation at 105Degree temp. but methanol bp 60Degree

Biocon,

1 3865

what is meaning of wet analysis.

Biocon, Shodhana,

5746

why using HCLO4 in potentiometry?. what are the chacterestics of HCLO4.

Biocon, RKM,

3694

what is peak purity? how may types of methods to determine peak purity?

Mylan,

3 14756

why using Potentometry What Purpose? differance between manual and potentiometry? why using Some of materials in usig potentiometry? What is use of mericuric acetate in Potentiometry

Biocon,

1 5744

iam using ph instrument lab india make.3ponit and 5point.in calibration time 3point slope will come 98.89and 96.87.that limit is 85 to 105.what basis slope will come.any calucalation between them.5point wiicome slope 99.89?why 3p0int came 2 values

1 5420

iam usig ph buffers merk. manually how to prepare ?

2277

Sulphated Ash incresed it will effect on product yield?

Biocon, Lupin,

3 5907

in loss on drying Why follows on constant weight not more than 0.5 mg, any region

Biocon,

1 14628

difference between selectivity and specificity

Troikaa Pharmaceuticals,

2 13203

What is Displacement Reaction .

2 4700

when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

ABC,

2041

differnc btw c18 and c-8 column

Cipla,

3 13342

use of stry light

1 7546


Un-Answered Questions { Chemistry }

why is acetic acid less conductive than hcl?

1162


Explain what is the dipole moment of chlorooctane?

1225


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

4268


Is cyclotetrane aromatic?

1288


IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?

2456


What is the monomer of polyethene?

1162


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

722


WHAT IS THE USE OF STARTER ?????????

2425


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1907


which are the diffrent batches in the pharmaceuticals?

820


What are the electrodes used in potentiometer titration?

1022


Which products will produce when acetic anhydride reacts with Ter-butanol, Sec-butanol, Iso butanol, Dimethylamine etc.

2865


how you fix the limits of impurities?

837


Why a1% value is used for some product ? What is the criteria for selection a1% value ?

2346


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1596