Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

if the neutral and ground of ups voltege are connected together in the source itslef then why the voltege b/w neutral and ground comes positive in some other destination inspite of having earth pit. how can we mimmise this?

MPL,

1 2962

How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.

Heisco,

2087

I want to know about DDCMIS in detail ? please explain it. Also give name of reference books in which it is explained in detail in very simple manner.

3754

regarding level tx i would like to know how to select the range of the level transmitter in a closed drum(steam drum or deaerator)?

1 7028

What is the relationship between Sensor

6 10919

there is one orifice plate already installed on 3" line, but my previous engineer(who is not working here) removed that tx, but now i want to take it in to the process, so now what i have to do now? flow fluid is hytherm oil of temp. 260deg & pressure is 3bar.

2 5570

what is mapping in instrumentation and control engineering

2 6676

hi this is noor i wnt know the procedure and precations errection for PRESSURE AND DP transmitters? how to take impusle line for level and flow?(water and steam) impulse line sizes? and type of material ? plz give me answer / reffer any website ? to me "mail2noor.hyd@gmail.com"

1 3923

What is the basic principle of vibration measurement by BENTLY NEVADA vibration measurement system? and Why it gives the -ve voltage output?

Ensol, GNFC, Reliance, Siemens,

14 134421

how the presure switches are calibrated? and what happen inside?

1 5786

Do you have reference list?

1788

i want know about capillary type LT transmitter installation. we can install any location in between to HP and LP leg?

2 10819

how to work MIL contol valve posistioner ?

ABB,

2083

how we can calibrate split range control valve?

1 9765

how we use the positioner feed back in split range control valves?

Tata Power,

1 10607


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Why MUX JB's are using only Temperature Element in Fundation field bus?

2263


give some question relative instrument fitter?

6201


when a magnet is heated?

1920


what are the definitions of input, output, command & signal according to instruments controlled by PLC using DCS System?

2061


Calibration of controller (pneumatic)

1907


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

2376


line up procedure for dp type flow transmitter?

1852


why would you like to join our company

1313


Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?

873


What are continuances of connecting earthing and shield of branch cables (instrument to Junction box), at the same earthing pot provided on JB? Is it ok, or may produce some problem? 

2434


I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.

2218


i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure

1856


how to turbine speed measurement?

1532


POSSITIVE PULSE IS APPLIED TO AN INVERTER INPUT.THE TIME FROM THE LEADING EDGE OF THE INPUT TO THE LEADING EDGE OF THE OUTPUT IS 10 ns. THE TIME FROM THE TRAILING EDGE OF THE INPUT TO THE TRYLING EDGE OF THE OUTPUT IS 8 ns. WHAT ARE THE VALUES OF tPLH and tPHL?

2229


How to calibration coriolis flow meter?

1756