What's -74C, dew point is better the -70C dew point
In draying unit
.
Answer / somasundar.ind@gmail.com
-70c is better for drying becoz higher temperature is favorable for drying
Is This Answer Correct ? | 0 Yes | 0 No |
For amonia manufacturing process if pressure, temperature would be increase over optimum level what would be happen?And what steps should be taken?
how to decide reflux ratio & its calculation
What does Dew point -40C mean in an air drying unit.
CHEMICAL MATERIAL BALANCE - EXAMPLE 2.1 : Two methanol-water mixtures are contained in separate tanks. The first mixture contains 40.0 wt % methanol and the second contains 70.0 wt % methanol. If 200 kg of the first mixture is combined with 150 kg of the second, what are the mass and composition of the product? The symbol of weight percent is wt %.
What factors should be compared when evaluating cooling tower bids?
UNIT OPERATION - EXAMPLE 9.4 : Acetone and ethanol are separated using a distillation column with a partial condenser and partial reboiler. An equimolar, sub-cooled liquid feed enters at 100 kmol / hr and condenses 1 mole of vapor for every 6 moles of feed. The separation requires a distillate vapor that is 95 mol % acetone and bottoms liquid that is 5 mol % acetone. The reflux is returned from the condenser to the column as a saturated liquid and the operation is run at (L / V) = 1.4 * (L / V) min. Assume constant overflow conditions. (a) Feed operating line is y = [ q / (q - 1) ] x - z / (q - 1) where z = 0.5 for equimolar liquid mixture of 2 components, q = (L'- L) / F where L' = L + F + (F / 6) for condensation of 1 mole of vapor / 6 moles of feed. What is y = f(x)? (b) The rectifying operating line is y = (L / V) x + (D / V) (xd) where (L / V) min goes through the points A (0.95, 0.95) and B (0.53, 0.69), V = L + D. What is y = f(x)? Let xd = 0.95. (L / V) min is the slope of the 2 points A and B.
Question 112 - In quantum computing, let the amplitude A = a | 0 > + b | 1 >, | a | | a | + | b | | b | = 1. Find the values of b if A = 0.8 | 0 > + b | 1 >.
BIOPROCESS ENGINEERING - EXAMPLE 14.1 : In differential centrifugation of cells with diameter D in centimeter, the square of D is given by D x D = [18n ln (RF / RI) ] / [ (RP - RFF) Wt ] where n is the fluid viscosity (poise), RF is the final radius of rotation (cm), RI is the initial radius of rotation (cm), RP is cell density (g / ml), RFF is the fluid density (g/ml), W the square for the rotational velocity in (radians / s) (radians / s), t is the time required to sediment from RI to RF (s). Derive an equation for W as a function for D, n, RF, RI, RP, RFF and t, with the stated units above, in radian & degree.
What does capacitor load means? How does it connect?
How is plate heat exchangers used in an ammonia refrigeration system?
What is some good advice for specifying allowable pressure drops in shell and tube exchangers for heavy hydrocarbons?
PROCESS DESIGN - EXAMPLE 21.2 : The names of the flow streams could be represented by : H1 for first hot stream, H2 for second hot stream, C1 for first cold stream, C2 for second cold stream. Data of supply temperature Ts in degree Celsius : 150 for H1, 170 for H2, 30 for C1, 30 for C2. Data of target temperature Tt in degree Celsius : 50 for H1, 169 for H2, 150 for C1, 40 for C2. Data of heat capacity Cp in kW / degree Celsius : 3 for H1, 360 for H2, 3 for C1, 30 for C2. (a) Find the enthalpy changes, dH for all streams of flow H1, H2, C1 and C2 in the unit of kW. Take note of the formula dH = (Cp) (Tt - Ts). (b) Match the hot streams H1 and H2 with the suitable cold streams C1 and C2 to achieve the maximum energy efficiency.