1 How to calculate dp transmitter
steam and water?
2 impulse line for liquid steam and
gas



1 How to calculate dp transmitter steam and water? 2 impulse line for liquid steam and gas..

Answer / carl_ellis

The DP pressure/flow transmitter is mounted above the pipe
for gas applications (empty impulse tubing).

The DP pressure/flow transmitter is mounted below the pipe
for liquid applications (liquid filled impulse tubing)

Steam flow applications using DP pressure transmitters were
historically mounted below-the-pipe (water filled impulse
tubing, frequently with condensate/seal pots), until
Emerson/Rosemount recently discovered that within certain
temperature limits, a DP transmitter close coupled on a
coplanar manifold to an Annubar averaging pitot tube can
survive steam temperatures mounted above-the-pipe.

See this link for Emerson's white paper on steam service
installation recommendations:
http://www2.emersonprocess.com/siteadmincenter/PM%
20Rosemount%20Documents/00870-0200-4809.pdf

Carl Ellis
Measure First

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

what are the pinciples & units of flow, level, temperature, pressure, quality.

1 Answers  


TRANSDUSER MOSTLY CONVERT WHICH ENERGY INTO ENERGY ?

6 Answers   DVC,


How ejector(or)evactor air pump is working in thermal power plant?

0 Answers  


In RS 500 SLC 5/03 input change one module card to another card, plz. give steps clearly.

0 Answers   BHL,


Emergency Shutdown Systems/ Plant Shutdown System.

0 Answers   CCIE,






what is the difference between SMART and tipical transmeter ?

3 Answers   Sirte Oil Company,


difference b/w single acting and double acting actuator by using application only?

2 Answers   McDermott,


NSV type probe stands for

0 Answers   Qatar Petroleums,


What is the constant voltage unit?

0 Answers  


what is the diffrence between mmwc and kg/cm2 for pressure measurment when we are using mmwc and when kg/cm2 and why????? ?? what is the reason

19 Answers   Ecoboard, Jindal, Sepco,


The wire is disconnected from the temperature sending unit (magnetic gauge). A voltmeter connected to the wire reads 0v. What does this indicate?

2 Answers  


HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.

0 Answers   Reliance,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)