what is the purpose of Buffer in any titration?Ex:In
determination of hardness of water we use ammonia
ammoniachloride buffer in titration with EDTA.Why?
Answers were Sorted based on User's Feedback
Answer / dinesh.m
use of the buffer is maintain the PH of the solution.........
Ex: Cyanodiole-HBr analysis in hplc v have use 3PH buffer solution as a mobile phase........
SUB:hard water means water having MgCl & CaCO3 r CaCl2
but v have use the ammonia buffer in titration with EDTA is complex formation.............
first we have add ammonia buffer to hard water MgCl2 is form the complex with NH3Cl as metal complex............After addition of EDTA. EDTA replaces the NH3 After completion of reaction the solution libarates EDT Acetate. This acetate react with E.Block-T give end point..............
Is This Answer Correct ? | 11 Yes | 15 No |
Answer / rakesh akhaury
Physical Chemistry, Analytical Chemistry ,General Chemistry ,Power Plant boiler water Analysis
Is This Answer Correct ? | 0 Yes | 4 No |
is there any exact definition for Theoritical plates ? chennu srinivas
who is the father modern liqiud chromatogrphy?
3 Answers Amneal Pharmaceuticals, Car Chem, Cipla,
What is the difference between kf and LOD
How can we detect a compound in hplc which does not have any chromofore?
What is Threshold in hplc?
how does h2so4 prevent oxidation of mohr salt before it is titrated?
In the gas chromatography what is used carrier gas and make up gas?
How can you prepare 0.05M Ammonium acetate volumetric solution?
1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer
Hello Dear all; I have a technical question related to analytical Chemistry, I have a sample of (40% w/w) Ferric Chloride solution (for water treatment purposes which consist a little portions of Ferrous Chloride and Hydrochloric acid. I need to know the methods to determine the percentages of each Ferrous Chloride and Chloride acid. Also I want to make sure that this solution is truly (40% w/w). So ANY CLUE !!! Thanks in advance.
calibrtion procedue of LC-MS
why we use x terra columns at higher ph ?