Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How decided 10 ppm standard solution in Swab, rinse method.?

Answers were Sorted based on User's Feedback



How decided 10 ppm standard solution in Swab, rinse method.? ..

Answer / venkat narayana

As per your standard test procedure,you decide yours specification, batch to batch (i.e same product)product change over 100 ppm standard we prepared and batch to another batch(i.e. product change) we have prepared 10 ppm standard

Is This Answer Correct ?    0 Yes 0 No

How decided 10 ppm standard solution in Swab, rinse method.? ..

Answer / kalyan

First we have to prepare 10 ppm standard solution with the respective solvent then we have to determine the abosorbance of that std by using uv after that we have to find the rinsed or swab sample absorbance by usig uv then we can calculate the result using the formula:(sample absorbance/standard absorbance)*10 then we will get the result in ppm

Is This Answer Correct ?    7 Yes 9 No

Post New Answer

More Analytical Chemistry Interview Questions

What is the importance of rrf in rs by HPLC?

1 Answers  


what is dead time in hplc?

3 Answers   Orchid,


what is deference b/w the working standard and reference standard

4 Answers  


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

0 Answers  


Data was integrated with RRT CONCEPT OR Overlay with SSTchrmatogram concept which is better?

1 Answers  


Please give idea about method development for cleaning method and how maco level establish

0 Answers  


if identification threshold crosses the limits then what next step?

0 Answers  


A new drug substance found fail to meet specification for an unknown Impurity during stability study(Specific change),how would further proceed?

2 Answers  


why we measure PH of a solution in PH only why not POH ?

1 Answers   Stellence Pharm Science,


Why base line not start from zero in GC Chromatography analysis.

1 Answers   Orchid,


Describe your experience with quality assurance and quality control analyses?

11 Answers   Aurobindo, Dr Reddys, MSC, Reddy Labs,


why should we do limit of stray light in UV calibration and why should use potassium chloride

2 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)