What is the Flow rate ?
Answers were Sorted based on User's Feedback
Answer / prateek jha
Flow Rate is usually used in industries working on
hydraulic and pneumatic areas to specify the amount of
working fluid passed across a fixed cross-section areas in
fixed time. Mostly, we describe flow rate in Litre Per
Minute means how much litres of working fluid has been
passed through a given cross-section area in One minute.
Flow Rate is independent of pressure in
hydraulic i.e liquid. but is dependent on pressure in gases
as gases are compressible at pressure. Hydraulic is also
compressible but at higher pressure.
| Is This Answer Correct ? | 10 Yes | 0 No |
Answer / bhaskar msc
flow rate is besed on the terms
ie, Turndown and Rangeability
turndown means ratio of full scale range to minimum scale
Rangeability means ratio of maximum rane to min range
thats the flow is based on the two terms
and i studied from PATRANBIES author
| Is This Answer Correct ? | 0 Yes | 0 No |
what is the diffirence between Earth and Neutral
What is profibus?
what is cavitation ?
What is a PID controller and how can it to applied to our everyday life?
Basics Instrumentation Question
1 Answers Advantek Fuel Systems,
dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,
what is the standard controll pressure
why can't we use 5-20mA standard or some other instead of 4- 20mA?
i am preparing for BARC ,so plz mail me how to prepare for BARC. ALSO IF POSIBLE SOME RELATED QUESTIONS. MY MAIL ID IS khushi_4uall2003@yahoo.co.in
What is three element drum level control system why its better than single element?
Why do we go for 4-20mA? why not other standara?
I work on a electronic positioner transmitter 4211 at the field.I connect my multimeter in series to get the current output then I calibrate it to 4ma in 0% of position of the valve and 20ma in 100% position of the valve.My problem is in the field I get the correct output current based on my multimeter but in the dcs they only receive 40% in a output 20ma of this positioner.Then I try to simulate in this analog card and they receive the equivalent percent on the value that I simulated.Is ther any possibility to reset the zero and span of this positioner 4211 fisher.And what other possibility I can do to fixed this.This is my email add ( landicho_randy@yahoo.com )
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)