What is the Flow rate ?

Answer Posted / prateek jha

Flow Rate is usually used in industries working on
hydraulic and pneumatic areas to specify the amount of
working fluid passed across a fixed cross-section areas in
fixed time. Mostly, we describe flow rate in Litre Per
Minute means how much litres of working fluid has been
passed through a given cross-section area in One minute.
Flow Rate is independent of pressure in
hydraulic i.e liquid. but is dependent on pressure in gases
as gases are compressible at pressure. Hydraulic is also
compressible but at higher pressure.

Is This Answer Correct ?    10 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the error values can accepted in flow transmitter calibration?could u give any formula for this?

1406


what is the importance of CV in the control valves? how it is calculated?

1961


How do you identify an orifice in the pipeline?

679


who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.

4273


How many types of sensor

1161






What is the use of control cable?

686


What is mean by analytical instrumentation?

1281


How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer

2314


We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.

1760


how to relay switch sense the fault?

2090


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1450


Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?

1775


HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.

1782


What is 3 element control system

1016


detail of mass flow meter pricipal

1828